id float64 3.83k 163k | accident_report dict | accident_type dict |
|---|---|---|
107,118.015 | {
"text": [
"Employee #1, employed by a drywall construction company, was working at a multiemployer construction project, a new residence. He was using a Falcon Sawhorse Model 130-FT as a stepladder and installing drywall. As Employee #1 walked side to side on the stepladder's top cap, he slipped and fell, a fal... | {
"type": "classification",
"value": [
"fall"
]
} |
103,964.015 | {
"text": [
"Employee #1, employed by a building maintenance and construction company, was on the roof of a building and investigating a noise reported by a tenant. He slipped on the roof's icy surface and fell to a lower roof, a fall height of approximately 15 to 20 feet. Emergency services were called, and Empl... | {
"type": "classification",
"value": [
"fall"
]
} |
105,519.015 | {
"text": [
"Employee #1, employed by a construction company, was on the roof of a building and setting up equipment in preparation for roofing repair work. He was standing near a skylight when he was struck by a gust of wind. Employee #1 fell through the skylight, a fall height of approximately 18 feet. Emergenc... | {
"type": "classification",
"value": [
"fall"
]
} |
103,805.015 | {
"text": [
"Employee #1, employed by a steel erection company, was installing steel decking for the roof of a two-story school addition. He stepped on an unsecured piece of decking material, which shifted and precipitated his fall from the roof, a fall height of 14.8 feet. Emergency services were called, and Emp... | {
"type": "classification",
"value": [
"fall"
]
} |
103,910.015 | {
"text": [
"Employee #1, employed by a construction company, was working at the remodeling of a two-story residence. He was using an extension ladder set on a level 10.33 feet below the surface and installing wood floor decking. As Employee #1 climbed down the unsecured ladder, the ladder slipped and flipped, an... | {
"type": "classification",
"value": [
"fall"
]
} |
106,455.015 | {
"text": [
"An employee was installing a metal roofing system at a two-story residence when he fell 17 feet and 11 inches. He was not wearing fall protection and was killed."
],
"children": {
"working_circumstances": {
"type": "extraction",
"text": [
"An employee was installing a meta... | {
"type": "classification",
"value": [
"fall"
]
} |
104,948.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in framing activities at a new commercial construction project on his first day at work. As he was walking on unsecured joists, he fell, a fall height of 9 feet. Emergency services were called, and Employee #1 was transported to the hospita... | {
"type": "classification",
"value": [
"fall"
]
} |
102,907.015 | {
"text": [
"Employee #1, employed by a plastering construction company, was working from a scaffold and engaged in exterior trim work at a residential construction project. The scaffold planks were slippery from rain and plaster, and the scaffold's railing had been removed. Employee #1 slipped and fell, a fall h... | {
"type": "classification",
"value": [
"fall"
]
} |
105,671.015 | {
"text": [
"Employee #1, employed by a plant maintenance services company, was working at a multiemployer job site. He was attempting to extract excess iron oxide from inside a kiln. Employee #1 was standing on an unguarded ramp used to access the kiln. He fell from the ramp into the kiln, a fall height of 30 fe... | {
"type": "classification",
"value": [
"fall"
]
} |
103,494.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a steel erection company, were engaged in steel erection work at a multiemployer construction project, a two-story commercial building. Employee #1 was straddling a steel beam and preparing to connect it to the top plate of a four by eight steel column. Cowork... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
105,587.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in carpentry work on the roof of a two-story residential structure, a multiemployer construction project. A piece of oriented strand board, blown by high winds, struck Employee #1's head and knocked him unconscious. Employee #1 fell from th... | {
"type": "classification",
"value": [
"fall"
]
} |
105,132.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a one-story commercial structure. He was working from an aerial lift in windy conditions and attempting to install metal siding on a wall. Employee #1 fell from the lift, a fall height of 20 feet. Em... | {
"type": "classification",
"value": [
"fall"
]
} |
103,240.015 | {
"text": [
"Employee #1, employed by a pipeline company, was connecting pipes inside a trench. The soil was saturated due to rainy weather. In addition, the trench box was set 4.83 feet above the bottom surface, which exceeded the allowable 2-foot gap. A trench wall caved in, and a large quantity of saturated so... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
103,140.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working from an aerial lift and engaged in maintenance work on an energized high voltage power line. Employee #1 sustained an electric shock and burn. Employee #1 was wearing the appropriate rubber and leather gloves, but the gloves were fo... | {
"type": "classification",
"value": [
"electrocution"
]
} |
103,300.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were engaged in trenching work. Coworker #1 was operating an excavator and lifting the excavator's bucket, which was full of gravel from the trench being dug. Employee #1 was holding plastic coverings down near the trench to collect the... | {
"type": "classification",
"value": [
"struck-by"
]
} |
103,279.015 | {
"text": [
"Employee #1 and Coworkers #1 and #2, employed by a construction company, were working at a multiemployer construction project, a one-story commercial building. After helping to cut and rig metal decking for hoisting by crane to the structure's roof, Employee #1 was sent to the roof to assist Coworker... | {
"type": "classification",
"value": [
"fall"
]
} |
104,503.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multifamily residential building that was being renovated. He was operating a grinder machine and using an extension cord that was not grounded and that was in contact with a wet surface. The extension cord was connected to a non-GFCI ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
105,012.015 | {
"text": [
"Employee #1 was setting up a chain link fence fabrication machine. The process required the unguarded machine's parts to be moving. Employee #1's sweatshirt caught on a bolt protruding from an unguarded rotating shaft, and his arm was pulled into the moving machine. A fuse blew and caused the machine... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
103,106.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were working at a multifamily residential building construction site. Employee #1 was holding a sign post that needed to be placed in the ground. Coworker #1 was operating a forklift that was being used to push the post into the ground.... | {
"type": "classification",
"value": [
"struck-by"
]
} |
103,055.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer building construction project. He was standing tied off on the building's first-story roof, which had a pitch of 1 to 12. Employee #1 leaned against a second-story wall that was wrapped in Tyvek. An open window in the wal... | {
"type": "classification",
"value": [
"fall"
]
} |
102,914.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing work at a two-story commercial building. As he attempted to connect his fall protection harness from one lifeline to another, he slipped on black ice and fell. Emergency services were called, and Employee #1 was transported to the hos... | {
"type": "classification",
"value": [
"fall"
]
} |
105,957.015 | {
"text": [
"Employee #1, employed by a demolition company, was working at a demolition project. An unattached fire damper fell and struck Employee #1. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for fractures to his shoulder, his spine, and two rib... | {
"type": "classification",
"value": [
"struck-by"
]
} |
107,748.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in framing work for a new two-story residence. As he ascended an 8-foot A-frame ladder placed on the hard dirt surface, the ladder kicked out, and Employee #1 fell, a fall height of 5 feet. Emergency services were called, and Employee #1 wa... | {
"type": "classification",
"value": [
"fall"
]
} |
105,580.015 | {
"text": [
"Employee #1 and Coworkers #1 and #2, employed by a municipal public works department, were working at the public works yard. Employee #1, operator of a John Deere 544G Number 30 front end loader, and Coworker #1, a mechanic, were instructed by Coworker #2, the supervisor, to work together to replace ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
107,105.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing repair work at a two-story residential structure. He was using an extension ladder to access the roof and provide materials to other employees. The unsecured ladder slipped, and Employee #1 fell and struck the concrete floor, a fall h... | {
"type": "classification",
"value": [
"fall"
]
} |
105,499.015 | {
"text": [
"Employees #1, #2, and #3, and Coworkers #1 and #2, employed by a drywall construction company, were preparing to install drywall to the ceiling of a pool party room, part of a multiemployer construction project, a new multifamily residential building. They were on a scaffold platform that had been lo... | {
"type": "classification",
"value": [
"fall"
]
} |
104,281.015 | {
"text": [
"Employee #1, Coworker #1, and four additional members of the work crew, employed by a paving company, were laying \"skin patches\" of sheet asphalt to level a college football field. They were using a Leeboy Conveyor Paver, two HAMM rollers, a backhoe, and several dump trucks. After they spread a loa... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
102,855.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a roofing company, were working at a multiemployer construction site, a three-story building. Employee #1 was climbing down an unsecured extension ladder. Coworker #1 did not maintain a hold on the ladder. The ladder, set on a gravel surface, slipped, and Empl... | {
"type": "classification",
"value": [
"fall"
]
} |
102,560.015 | {
"text": [
"Employee #1, employed by a construction company, was working at the site of a four-story building project. A scissor lift was being moved by a forklift, and Employee #1 was attempting to stabilize the unsecured load. The scissor lift slipped and fell onto Employee #1. Emergency services were called, ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
102,501.015 | {
"text": [
"Employee #1, a carpenter employed by a construction company, was installing Simon concrete forms inside an excavation. The excavation measured approximately 11 feet long by 22 feet wide by 4 feet deep. An unstable spoil pile along the west side of the excavation collapsed onto Employee #1 and pinned ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
102,434.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working from an aerial lift and changing light pole fixtures. He moved too close to a live power line and sustained an electrical shock. Emergency services were called, and Employee #1 was transported to the hospital, admitted, and treated ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
102,664.015 | {
"text": [
"Employee #1, employed by a steel erection company, was working at a construction site. He was moving an I beam when he inadvertently dropped the beam, which fell onto and crushed his finger. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated f... | {
"type": "classification",
"value": [
"struck-by"
]
} |
103,598.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a new single-family residence. He was inside a trench that was approximately 5 feet wide and ranged in depth from 7.25 feet to 9 feet. Employee #1 was using a shovel to clear excess dirt and sand tha... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
102,113.015 | {
"text": [
"Employee #1 and a coworker, employed by a construction company, were working at a multiemployer road project. Employee #1 had just retrieved a backpack left in a skid steer vehicle when he turned over the vehicle's operation to the coworker. The backpack's straps caught on the skid steer's controls, ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
104,811.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer project. He was conducting injection testing of breakers when he reached into a breaker panel that apparently had not been deenergized. An electric arc flash occurred, and Employee #1 sustained burns to his upper body. Em... | {
"type": "classification",
"value": [
"electrocution"
]
} |
102,015.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a commercial building. He was operating a cement mixer when his hand became caught in the unguarded opening at the bottom of the machine. The machine's rotating blade lacerated his finger. Emergency ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
101,619.015 | {
"text": [
"Employee #1, the owner of a construction company, was using a pneumatic nail gun to erect the wood frame for a residential structure. The nail gun inadvertently discharged, and he was struck by a 2.5-inch nail between the bridge of his nose and his eye socket. Emergency services were called, and Empl... | {
"type": "classification",
"value": [
"struck-by"
]
} |
101,609.015 | {
"text": [
"Employee #1, employed by a concrete company, was pouring concrete at a multiemployer construction project. An unbraced 8-foot high chain link fence fell on him. Emergency services were called, and Employee #1 was transported to the hospital, where he was admitted and treated for a fractured left ankl... | {
"type": "classification",
"value": [
"struck-by"
]
} |
105,633.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a five-story commercial building. He was functioning as a tag liner for steel erection. Employee #1 walked to an I-beam that was being hoisted. The beam, which weighed 1,500 pounds, was 32 feet long,... | {
"type": "classification",
"value": [
"struck-by"
]
} |
101,452.015 | {
"text": [
"Employees #1 and #2, employed by an electrical contractor, were engaged in electrical work at the construction site for a multifamily residential building. They were installing a busbar with the electrical power turned on when Employee #1 touched the busbar. An arc flash ensued. Emergency services we... | {
"type": "classification",
"value": [
"electrocution"
]
} |
100,952.015 | {
"text": [
"Employee #1, employed by a construction materials company, was sorting through wood panels on a push truck. The panels weighed up to 300 pounds each, and the push truck, which measured 10 feet long by 3 feet wide, lacked brakes for locking its six wheels. Employee #1 stepped on the push truck, and 10... | {
"type": "classification",
"value": [
"struck-by"
]
} |
102,109.015 | {
"text": [
"Employee #1, employed by a construction contractor, was working at a multiemployer construction project, a new one-story commercial building. He climbed a 14-foot steel form, used in the construction of a concrete column, to disconnect it from a crane. The form, which weighed more than 1,000 pounds, ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
104,229.015 | {
"text": [
"Employee #1, employed by a modular home builder, was helping to install modular wall panels at a multiemployer construction project, a three-story multifamily residential building. The wind caused a panel to shift and break apart. Employee #1 was struck in the head. Emergency services were called, an... | {
"type": "classification",
"value": [
"struck-by"
]
} |
101,232.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a building services company, were cleaning the exterior windows of a twelve-story office building. They were suspended from a rooftop anchor system and had descended from the fourth to the third floor, 30 feet above the surface. Employee #1's primary lifeline ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
104,511.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were engaged in the construction of a new gas station. They were using a John Deere backhoe loader, Identification Number 1TO310ELVGG297191, to unload sumps from a flatbed trailer into the backhoe's bucket. Coworker #1, Employee #1's su... | {
"type": "classification",
"value": [
"struck-by"
]
} |
100,453.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a company in the renewable energy industry, were working at the construction site for a new project. They were standing in an elevator that failed to move and were attempting to troubleshoot the problem. Employee #1 climbed halfway out through the overhead hat... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
103,174.015 | {
"text": [
"Employee #1, employed by a construction company, was doing exterior carpentry repair and maintenance at a two-story commercial building. He was using a rope and pulley to raise a piece of lumber when he felt a splinter in his hand. He became distracted, and the lumber fell back down onto his left arm... | {
"type": "classification",
"value": [
"struck-by"
]
} |
100,053.015 | {
"text": [
"Employee #1, employed by a construction company, was working inside a tee-trench that measured 6.5 feet deep by 4 feet wide. He was connecting a new water pipe that had been installed. Most of the trench was shored, but one inside corner was not protected completely due to an electrical line obstruct... | {
"type": "classification",
"value": [
"struck-by"
]
} |
101,174.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a pipeline company, were working at an excavation alongside a busy road. Employee #1, the site foreman, was inside a 5-foot excavation and overseeing the work crew's digging around gas pipes. The bucket of a backhoe truck was inside the trench and being used t... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
103,863.015 | {
"text": [
"Employee #1, employed by a healthcare consortium, was working in a trench at a depth of approximately 6.5 feet. The trench's vertical walls had no shoring or protective devices. Employee #1 was manually clearing dirt away from a 6-inch diameter water pipe when part of the trench wall behind him colla... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
100,150.015 | {
"text": [
"Abstract: There are two inspections associated with this investigation",
"1272750, and 1272751. This narrative is based on inspection number 1272750. Employee #1 was working for a site preparation contractor. He was at a worksite where an existing residence was being renovated. He was removing ro... | {
"type": "classification",
"value": [
"struck-by"
]
} |
100,195.015 | {
"text": [
"Employee #1, employed by a boiler services company, was conducting maintenance on a boiler. Lockout-tagout was not implemented. As Employee #1 removed the v-belt, the boiler's drive system activated. Employee #1's left middle finger was caught in the v-belt/pulley, and the fingertip was amputated. Em... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
99,979.015 | {
"text": [
"Employee #1, employed by a building contractor, was trying to remove a piece of cutout metal from a portable hydraulic punch press. His finger was inside the press when he inadvertently stepped on the control pedal. The press began to cycle, and Employee #1's left index finger was partially amputated... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
99,937.015 | {
"text": [
"Employee #1, employed by a construction company specializing in grain storage, was in the process of constructing a storage structure. He was kneeling on the ground and working with a metal rafter which lay flat on the ground. A gust of wind blew another nearby rafter, which struck and fell on top of... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
101,130.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were working at a pile driver. Employee #1 was unhooking a rigging chain from the pile driver. Coworker #1, the pile driver operator, raised the driver hammer before the rigging chain was detached. Employee #1's finger was pinched betwe... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
104,327.015 | {
"text": [
"Employee #1, an apprentice electrician, and Coworker #1, a journeyman electrician, both employed by an electrical services company, were engaged in electrical work at a job site. Coworker #1 was changing out buss fingers as Employee #1 stood behind and held open the cabinet door. Employee #1 was not ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
99,517.015 | {
"text": [
"Employee #1, the foreman, and Coworkers #1 and #2, employed by a construction company, were working at a multiemployer project, a bridge construction. They were dismantling a mobile crane for transport off-site. In an attempt to lift the crane's rear outrigger, which weighed 5,600 pounds, and to plac... | {
"type": "classification",
"value": [
"struck-by"
]
} |
99,683.015 | {
"text": [
"Employee #1, employed by an industrial services company, was driving a dual axle dump truck and hauling gravel. The truck's brakes failed. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for multiple injuries, including eight fractured ribs... | {
"type": "classification",
"value": [
"struck-by"
]
} |
99,215.015 | {
"text": [
"Employee #1 was talking to a dump truck operator. Nearby, a loader was being used to load material into the dump truck. The loader operator lost sight of Employee #1. The loader backed up pinning him between the loader and dump truck. Employee #1 suffered crushing injuries that killed him"
],
"ch... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
100,392.015 | {
"text": [
"Employee #1 and Coworkers #1 and #2, employed by a construction company, were installing casing for an existing underground water/sewer line. Coworker #2 was operating a crane and Coworker #1 was flagging/providing direction to Coworker #2. Coworker #1 made the wrong call, and the crane lifted the ca... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
99,400.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were operating earth-moving scrapers at a multiemployer construction project, a new residential building development. They were grading the unimproved lots. Employee #1, who was operating a Caterpillar 637 Scraper, Identification Number... | {
"type": "classification",
"value": [
"struck-by"
]
} |
99,641.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were engaged in excavation and trenching work at a residential property. They were tasked with removing an existing drainage pipe and replacing it with a new pipe. Coworker #1 was operating excavation equipment, and Employee #1 was work... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
98,373.015 | {
"text": [
"Employee #1, employed by a construction company, and Coworker #1 were working at a multiemployer construction project that involved an excavation. Employee #1 was cleaning out residual debris from the excavation. Coworker #1, a backhoe operator, was preparing to drive the backhoe forward and out of t... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
99,243.015 | {
"text": [
"Employee #1, employed by an electrical services company, was at a worksite and preparing to work on an irrigation booster. As he attempted to de-energize and disconnect a transformer, he disconnected the wrong transformer, one that was still energized. An arc flash ensued, and Employee #1 received fl... | {
"type": "classification",
"value": [
"electrocution"
]
} |
98,162.015 | {
"text": [
"Employee #1 and Coworker #1, employed by a construction company, were working at a multiemployer construction project. Employee #1 was unhooking rigging chain from a pile driver operated by Coworker #1. Employee #1 raised the pile driver's hammer before the chain was cut loose. Employee #1's finger w... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
98,404.015 | {
"text": [
"Workers employed by a county transportation department were patching a road. They had parked their vehicles inside the marked-off work zone. The moving vehicle's brakes failed while traveling down a hill, the driver lost control, and the vehicle ran into the rear of a worker's parked vehicle. No one ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
97,810.015 | {
"text": [
"Employee #1, employed by a construction company, was performing electrical work at a multiemployer construction site, a medical building. He was installing a new circuit breaker in an existing, live, 480-volt circuit breaker panel. Three straps, each with one screw, were required to install the break... | {
"type": "classification",
"value": [
"electrocution"
]
} |
101,403.015 | {
"text": [
"Employee #1, employed by a drywall construction company, was loading painting materials into a vehicle in preparation for painting newly constructed residences at a job site. He was standing behind his vehicle's tailgate when a second, driverless vehicle began to roll toward him. The second vehicle s... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
97,665.015 | {
"text": [
"An employee was working for a firm that provided waste management services. He was replacing a tine arm on the bucket of a crane used in a garbage pit. The tine arm was held in place by two pins. The employee did not secure the tine arm. As he was removing the two pins for replacement, the arm shifte... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
97,346.015 | {
"text": [
"Employees #1, #2, and #3, employed by a roofing company, were engaged in roofing work at a residential building construction site. They were installing roof shingles when lightning struck the roof and made contact with all three employees. Emergency services were called to transport the injured emplo... | {
"type": "classification",
"value": [
"electrocution"
]
} |
101,470.015 | {
"text": [
"Employee #1, employed by a construction company specializing in solar power systems, was working at a jobsite. He was checking the status of the task of pulling wire from a reel into a conduit. He walked up to the wire reel, which weighed approximately 500 pounds and was attached to a Skytrak-style f... | {
"type": "classification",
"value": [
"struck-by"
]
} |
102,311.015 | {
"text": [
"Employee #1, a carpenter employed by a construction company, was part of a crew setting wooden forms for a two-story building's 25-foot tall concrete column. As Employee #1 was climbing down from the top of the wooden form, which was not supported/braced, the form started to fall toward the second fl... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
97,371.015 | {
"text": [
"An employee was installing gutters and downspouts on the third level of a newly built townhouse. During work, high winds caused the employee to move a metal ladder he was using from the north side of the house when the ladder contacted overhead power lines. The employee was electrocuted."
],
"chi... | {
"type": "classification",
"value": [
"electrocution"
]
} |
98,835.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working in a building's corridor. He was changing the direction of an exit sign. As he attached the exit sign to the ceiling, Employee #1 touched an energized wire. He received an electric shock. Emergency services were called, and Employee... | {
"type": "classification",
"value": [
"electrocution"
]
} |
101,836.015 | {
"text": [
"Employee #1 and Coworker #1, employed by an excavation company, were working alongside a road. They were preparing to install a precast manhole in a trench. Coworker #1 was operating a hoisting machine, and Employee #1 was in the trench and disconnecting the load (the precast manhole). Coworker #1 ho... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
97,137.015 | {
"text": [
"Employees #1 and #2, employed by a construction company, were engaged in rigging work at a construction site. They were working from a crane. A metal rigging cable came too close to a power line, and an electric arc occurred. The two employees sustained electrical shocks. Emergency services were call... | {
"type": "classification",
"value": [
"electrocution"
]
} |
97,024.015 | {
"text": [
"A 52 year old male employee was installing concrete forms for a foundation addition to an existing single family home. The employee, the crew foreman, was using a Skilsaw hand held circular saw which was plugged into an extension cord which was plugged into a second extension cord. The second extensi... | {
"type": "classification",
"value": [
"electrocution"
]
} |
97,123.015 | {
"text": [
"Employee #1, employed by an electrical services company, was engaged in electrical installation work at the multiemployer construction site for a large office complex. He was using a Maxis 3K Cable Puller powered by a Milwaukee Super Hawg Drill to pull wires through an electrical panel in a server ro... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
99,249.015 | {
"text": [
"Employee #1, employed by a company specializing in transportation-related electrical services, was helping repair the brakes on the back of a bread truck. He was under the truck, which was jacked up with no jack stands. The jack sank into the soft dirt, crushing Employee #1. Emergency services were c... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
101,671.015 | {
"text": [
"Employee #1, employed by an electrical supply company, was working at a multiemployer job site. Employee #1 had climbed a ladder to roll and bundle data cable hanging from the ceiling. The employee did not see a junction box hanging open from the ceiling with an exposed live wire. The wire struck Emp... | {
"type": "classification",
"value": [
"electrocution"
]
} |
96,911.015 | {
"text": [
"Employee #1, a foreman, and Coworker #1, employed by an electrical contractor, were working at a multiemployer job site, the construction of a new commercial building. They were engaged in interior electrical work, installing video monitors. As they moved a boxed video monitor on a wooden dolly from ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
96,278.015 | {
"text": [
"Employee #1, employed by a concrete drilling contractor, was working at a commercial building. He was inside an electrical cabinet and drilling three 5-inch holes in the cabinet's concrete floor. Power to the cabinet's electric panel was not shut off. Employee #1 was electrocuted. Emergency services ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
96,453.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working at a multiemployer job site. He was installing grounding bushing on the inside of an electrical panel to which power had been turned off. The power company turned on the electrical power, and 480 volts flowed to the panel. An arc fl... | {
"type": "classification",
"value": [
"electrocution"
]
} |
97,648.015 | {
"text": [
"Employee #1, employed by a company providing fire sprinkler systems, was engaged in fireproofing work at a seven-story building. He was gathering tools and material to extend a standpipe up one floor. Employee #1 began to unscrew the 6-inch Grinnell Mechanical Grooved Lock-In Cap with a ratchet and p... | {
"type": "classification",
"value": [
"struck-by"
]
} |
95,671.015 | {
"text": [
"Employee #1, employed by an electrical services company, was part of a work crew working in a residential neighborhood and preparing to string wire from a utility pole that another crew had replaced. Employee #1 was assigned to prep cable on the ground next to a bucket truck. For an undetermined reas... | {
"type": "classification",
"value": [
"electrocution"
]
} |
95,757.015 | {
"text": [
"Employee #1 and coworkers, employed by a concrete construction company, were working at a single family residential construction site. They were engaged in the installation of a concrete garage floor measuring 20 feet wide and 22 feet 6 inches long. In order to ensure an even concrete pour, the emplo... | {
"type": "classification",
"value": [
"struck-by"
]
} |
99,803.015 | {
"text": [
"Employee #1, employed by a concrete pumping equipment rental company, was working at the construction site of a multifamily residential project. Employee #1, operating a 1999 Putzmierter concrete pump truck, had delivered concrete to the site. He then began to perform a washout on the concrete pump t... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
95,228.015 | {
"text": [
"Employee #1 and Coworkers #1 and #2, employed by a plumbing and heating company, were leaving the construction site for a new hospital at the end of their shift. Coworker #3, an excavator operator, was working outdoors. Employee #1 and Coworkers #1 and #2 left the building and walked along an un-deli... | {
"type": "classification",
"value": [
"struck-by"
]
} |
97,507.015 | {
"text": [
"Employee #1, employed by an electrical services company, was upgrading the electrical equipment at a commercial building. He tried to install a ground wire on an electrical panel while electrical power was flowing from the panel. Employee #1's left hand made contact with a live 277-volt busbar, and a... | {
"type": "classification",
"value": [
"electrocution"
]
} |
97,550.015 | {
"text": [
"Employee #1, employed by a demolition company, was working at a multi-employer construction site, of a commercial building. He was demolishing a first floor interior wall. Electrical power in the building had not been shut off, and nearby electrical wires had current flowing through them. Employee #1... | {
"type": "classification",
"value": [
"electrocution"
]
} |
95,000.015 | {
"text": [
"An employee was operating a bulldozer crushing and moving garbage. The employee fell out of operator's cabin of bulldozer as it was moving sharply downhill. The employee was crushed and suffered blunt force trauma to hips and legs. The employee was killed by heavy equipment, either by tracks of his d... | {
"type": "classification",
"value": [
"struck-by"
]
} |
94,416.015 | {
"text": [
"Employees #1 and #2, employed by a construction contractor, were engaged in trench excavation work related to a commercial building construction project. Employee #1 was taking his lunch break while standing inside the 2- to 3-foot excavation, which had just been dug next to an existing concrete bloc... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
94,138.015 | {
"text": [
"An employee and a coworker entered an unprotected excavation approximately 15-18 feet deep. The employee was talking to his supervisor approximately 10 feet away from an excavation wall when a section of the wall partially collapsed. The employee was struck by soil material falling down. The employee... | {
"type": "classification",
"value": [
"struck-by"
]
} |
94,988.015 | {
"text": [
"An employee and coworkers were paving a parking lot. The employee was too close to a backhoe which ran over his foot. The employee fractured his ankle for which he was hospitalized."
],
"children": {
"working_circumstances": {
"type": "extraction",
"text": [
"An employee a... | {
"type": "classification",
"value": [
"struck-by"
]
} |
93,557.015 | {
"text": [
"An employee was working as part of a construction crew and moving temporary road signage from one section of highway to another to prepare for concrete culvert construction. The employee was riding in the back of a 2007 Dodge 3500HD Dually with the tailgate down picking up the fabric signs as a cowor... | {
"type": "classification",
"value": [
"struck-by"
]
} |
93,292.015 | {
"text": [
"An employee was performing his duties as a spotter/ inspector and was walking behind a Kawasaki front end Loader, Serial Number VG7N38 that was loading trash into trailers that were parked in the middle of the recycling yard. The loader operator scooped a load of trash and began to back and turn the ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
93,333.015 | {
"text": [
"Employee #1, employed by a construction-related services company, was performing electrical work. He was terminating a ground wire onto a mechanical lug on the lower half of a 480-volt, 200-amp disconnect. When he loosened the mechanical ground lug, the ground wire came into contact with an energized... | {
"type": "classification",
"value": [
"electrocution"
]
} |
94,450.015 | {
"text": [
"An employee was using a forklift to deliver construction materials when two metal fence panels on the ground got blown by a gust of wind into the forklift. The employee was struck by the fencing, sustaining a fractured right arm and multiple lacerations. He was hospitalized and received treatment for... | {
"type": "classification",
"value": [
"struck-by"
]
} |
92,314.015 | {
"text": [
"Employee #1 who was a superintendent for a road crew, was operating a Crawler Dozer to free up the assigned operator to use another piece of heavy equipment. Employee #1 was grading some compacted soil on the side of a roadway where another lane was being added. The employee was not wearing a seatbel... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
90,735.015 | {
"text": [
"An employee was operating a Caterpillar telehandler forklift Model 1055C, serial number KDE01436. The employee was traveling down a dirt slope ramp that was approximately twenty percent grade with the forks downgrade and the plate compactor attached to the fork with a chain. The employee was driving ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.