id float64 3.83k 163k | accident_report dict | accident_type dict |
|---|---|---|
126,971.015 | {
"text": [
"An employee, working for a rain gutter contractor, was installing flashing for a gutter installation on the first-floor roof of a two-story residential structure. The employee was not using personal fall protection, lost footing and balance, and fell approximately 10.5 feet to the ground. The employe... | {
"type": "classification",
"value": [
"fall"
]
} |
125,354.015 | {
"text": [
"Employee #1, employed by a roofing company, was handling roofing insulation sheets on the roof of a four-story commercial building. He was close to the edge and outside of the warning line when he fell, a fall height of 60 feet. A witness reported that a gust of wind blew Employee #1 off the roof. Em... | {
"type": "classification",
"value": [
"fall"
]
} |
125,314.015 | {
"text": [
"Employee #1 and a Coworker, employed by a construction company, were engaged in digging a trench for a pipeline. Employee #1 was standing on the conveyor of a shut down Wolfe Man 8000 Trencher and was cleaning dirt from the machine. The coworker, who was the machine operator, caught his shirt on the ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
125,113.015 | {
"text": [
"Employee #1 and a coworker, employed by a waterproofing company, were installing waterproofing material under the gutter of a one-story commercial building. They were working from a scissor lift approximately 20 feet above the paved surface. As the work was finishing, the coworker, who was operating ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
125,037.015 | {
"text": [
"Employee #1, a construction flagger, was conducting traffic control during a maintenance and repair project. At this time, an impaired driver drove their vehicle through the work zone and accidentally struck Employee #1, currently working on foot, within the construction site. Afterwards, Employee #1... | {
"type": "classification",
"value": [
"struck-by"
]
} |
130,503.015 | {
"text": [
"An employee, a delivery driver, was making a delivery of drywall sheets to the job site. The employee was using a drywall cart to deliver sheets of drywall to the construction location inside the building. The drywall cart had 5 bundles of 10 drywall sheets each on it. The employee was pushing it dow... | {
"type": "classification",
"value": [
"struck-by"
]
} |
125,857.015 | {
"text": [
"Employee #1, employed by a construction company, was painting the exterior of an existing two-story multifamily residential structure. As he moved an aluminum extension ladder away from the structure, the wind caught the ladder, and the ladder made contact with a nearby primary electrical power line.... | {
"type": "classification",
"value": [
"electrocution"
]
} |
124,897.015 | {
"text": [
"Employee #1 and coworkers, employed by a construction company, were working at the intersection of two roads that had been closed off. Their assignment was to install a 42-inch corrugated plastic pipe approximately 24 feet below the surface. Employee #1 was working at the bottom of the trench and ass... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
124,377.015 | {
"text": [
"An employee was unloading material (shingles) at a new construction job site, while replacing a forklift attachment in a truck with a crane. The employee got his left hand into a pinch point, while trying to release a crane hook on the delivery vehicle. The employee suffered a partial amputation of t... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
125,651.015 | {
"text": [
"An employee, working for a contracting company erecting steel at a power plant, was guiding an 18-foot I-beam that was elevated 5 feet and attached by a magnet to the hoisting mechanism of a dedicated pile driver. When the I-beam was being hoisted, the bolt attached to the U-bolt holding the strap/ma... | {
"type": "classification",
"value": [
"struck-by"
]
} |
124,436.015 | {
"text": [
"An employee, working for a framing and carpentry company, was assembling prefabricated walls for use by the construction industry. The employee was operating a compound miter saw that was secured to a table. The employee was in the process of making small blocks of wood from a 4\"x6\" board. The empl... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
125,237.015 | {
"text": [
"Employee #1 and Employee #2 were performing framing activities on the fourth floor of an apartment building. Employee #1 and Employee #2 were standing up a full sheathed 12 ?-foot wide by 18 ?-foot long wooden exterior wall. The nails securing the base failed and the bottom section of the wall kicked... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
123,698.015 | {
"text": [
"Employee #1 and a coworker were engaged in the demolition of a building. Employee #1 was loading steel doors into the dozer bucket attachment of the CAT 252B skid loader operated by the coworker, so the doors could be moved into the dumpster. Employee signaled the operator to lift the bucket. Instead... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
123,551.015 | {
"text": [
", an employee was working in an unprotected trench laying power lines when the trench collapsed on him. The employee was hospitalized to treat fractures to both his tibia and fibula."
],
"children": {
"working_circumstances": {
"type": "extraction",
"text": [
"an employee ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
123,234.015 | {
"text": [
"Employee #1, employed by a construction company, was directing traffic as his coworkers installed a pipe below a road. He was working without wearing high-visibility clothing or using a stop/go paddle, and warning signage was not in place. A motor vehicle struck the employee. He was killed by the imp... | {
"type": "classification",
"value": [
"struck-by"
]
} |
123,235.015 | {
"text": [
"Employee #1, employed by a utility company, was replacing a utility pole. An insulator on the pole failed, resulting in an electric arc. The electric current travelled through Employee #1, who was electrocuted."
],
"children": {
"working_circumstances": {
"type": "extraction",
"te... | {
"type": "classification",
"value": [
"electrocution"
]
} |
126,255.015 | {
"text": [
"An employee working as a glazier glass contractor was installing glass panels on a residential elevator shaft. The employee was working from the top of the elevator car. The pendant switch operating the elevator malfunctioned and allowed the elevator to keep traveling upward with the employee still o... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
123,826.015 | {
"text": [
"An employee was working as a construction laborer applying stucco for a residential construction contractor. The employee was attempting to climb a scaffold at a residential construction site. The scaffolding pulled away from the building causing the employee to fall to the ground below. The scaffold... | {
"type": "classification",
"value": [
"fall"
]
} |
123,726.015 | {
"text": [
"Employee #1, employed by a demolition and construction company, was working at the company's facility. He was instructed to pick up two packages being delivered to the front gate by a delivery driver. He entered the cab of a LULL forklift and proceeded toward the gate. While operating the forklift, E... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
126,979.015 | {
"text": [
"An employee was performing flagging activities while a coworker was operating a Gradall rough terrain forklift (Model: 554D-10). As the coworker turned out onto the road with the forklift, they struck the employee in the feet and legs, causing him to fall. The coworker stopped the forklift to offer a... | {
"type": "classification",
"value": [
"struck-by"
]
} |
123,872.015 | {
"text": [
"An employee was operating a left screed extender on an asphalt paver. The employee's hand was resting on the left remote-control box, and he accidentally bumped the control, causing the extender to extend. The employee's left pinky became caught between the extender and a concrete wall. The employee ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
122,294.015 | {
"text": [
"Employees #1 and #2, employed by a railroad, were doing maintenance work in a power plant yard. Employee #1 was working from a ladder and changing fuses on a transformer. He was wearing fire resistant gloves but not rubber gloves. Employee #2, who was wearing a fire resistant coat, was on the ground ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
122,108.015 | {
"text": [
"An employee was working for a plumbing, heating, and air conditioning contractor. He was a concrete and terrazzo finisher. He was cleaning the paddles of a concrete mixer by pouring water into it from a 5-gallon (18.9-liter) bucket. The mixer was attached to a Kubota Model SVL 95-2S track loader, wit... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
122,216.015 | {
"text": [
"An employee was working as a structural metal worker for a structural steel and precast concrete contractor. He was erecting structural steel on a project of new work on or an addition to a hotel. The employee was part of a group of iron workers. They were working in the building's basement. A 30-foo... | {
"type": "classification",
"value": [
"struck-by"
]
} |
125,828.015 | {
"text": [
"Two employees were working for a framing and drywall contractor. They were working at a multi-employer site. They were carpenters, part of a project of new work on or an addition to a six-story building, a hotel. They were installing bracing on the underside of a roof section that was suspended in th... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
122,833.015 | {
"text": [
"Employee #1 was a construction laborer on the night crew, working as a fulltime employee for this employer. Employee #1 was standing alongside and under the G&Z paving machine, working in his required position when the paving machine is in operation and moving. Employee #1 was directly engaged in the... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
125,370.015 | {
"text": [
"An employee working as a carpenter for a residential remodeler was working on a residential construction site. The employer has only 1 to 2 employees. The employee was repairing side panels on the south side of a house on a narrow walkway. A scaffold had been erected in the walkway, which was approxi... | {
"type": "classification",
"value": [
"struck-by"
]
} |
126,745.015 | {
"text": [
"An employee was working as a construction laborer for a landscaping architectural service. He was moving a wheelbarrow full of dirt. He lost his balance and fell onto a steel rebar. The rebar was capped with a cap that was not approved, designed, or intended for protection from impalement. The cap br... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
121,680.015 | {
"text": [
"An employee working as a City Sewage Treatment Plant Operator was installing 8-inch PVC sewer line in a trench. A trench box was available since the trench was approximately 6 feet deep but it was not being used. The sidewall of the trench collapsed on the employee striking the employee and crushing ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
125,407.015 | {
"text": [
"An employee working as a construction laborer for a water and sewer pipeline contractor was operating a SkilSaw Model SPT77W worm drive circular saw. The employee was using the saw to cut wedges from a 2-inch by 4-inch board. The employee had worked for the employer for approximately 8 years at the t... | {
"type": "classification",
"value": [
"struck-by"
]
} |
125,941.015 | {
"text": [
"An employee was working as a construction laborer for a structural steel and concrete contractor. The employee was working with a coworker using a powered industrial vehicle (PIV) to pull a rebar cage off a truck. The employee was holding a tag line for the suspended load. The cage became lodged and ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
125,381.015 | {
"text": [
"An employee was performing framing and cutting work on a new residential construction project. The employee was using a Skilsaw portable powered circular hand saw (model SPT77WML). He was cutting the end of an installed floor joist with one hand on his saw that was positioned on his knee directly. Th... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
121,135.015 | {
"text": [
"An employee working as a carpenter apprentice for a residential building contractor was working on exterior siding. The employee inadvertently activated the trigger of a nail gun while removing it from her tool belt. The employee then accidentally hit her right foot causing the gun to shoot a nail in... | {
"type": "classification",
"value": [
"struck-by"
]
} |
121,564.015 | {
"text": [
"An employee working as a laborer for a flooring contractor was using a DeWalt Model #DWE7480 10-inch table saw to cut flooring. The table saw was unguarded and while he was cutting the flooring his hand slipped and came in contact with the blade. The employee partially amputated a finger, requiring h... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
121,365.015 | {
"text": [
"An employee working for a structural concrete contractor was using a Hilti TE 50 hammer drill on a concrete surface. The drill had a broken chuck causing the employee to catch his left hand between the drill bit and chuck. The employee amputated his pinky finger and was hospitalized."
],
"childre... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
121,278.015 | {
"text": [
"An employee working as a laborer for an oil and gas pipeline construction contractor was reassembling a manhole cover. The employee was using a DeWalt DWE 4 1/2\" angle grinder with no guard installed and no current ring test. A cup flew off the grinder striking the employee in the hand and knee. The... | {
"type": "classification",
"value": [
"struck-by"
]
} |
120,592.015 | {
"text": [
"Employee #1 was driving a BOBCAT, a utility vehicle used to pick up product during a commercial construction project, and inadvertently drove the BOBCAT directly into a parked trailer bed. As a result, Employee #1 sustained blunt force trauma injuries from contact with the parked trailer bed and was ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
120,728.015 | {
"text": [
"A crew of five carpenters were installing a roof truss system when the trusses collapsed. The employer did not ensure adequate ground and truss bracing were installed on the single-story wood framed building. The employee was hospitalized to treat unspecified fractures."
],
"children": {
"wor... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
120,424.015 | {
"text": [
"Employee #1 was preparing to install a wire reinforcement panel, on top of a concrete block wall, during residential construction. Employee #1 was moving wire reinforcement, within 54 inches, of a 7.2 kV, overhead transmission power line and accidentally, contacted the power line. Employee #1 suffere... | {
"type": "classification",
"value": [
"electrocution"
]
} |
120,425.015 | {
"text": [
"Employee #1 was cleaning up the worksite, after installing new exterior cladding (roofing shingles), during residential construction. Afterwards, Employee #1 then carried a ladder, in an extended and upright position, and came within (4 feet) of a high voltage, overhead power line. As a result, a con... | {
"type": "classification",
"value": [
"electrocution"
]
} |
119,942.015 | {
"text": [
"Employee #1 and a coworker, employed by a water and sewer line construction company, were drilling to replace the water lines to houses along a roadway. The Vermeer D10x15 horizontal directional drill's vice clamp needed repair. As the coworker sat on the drill's operator seat, Employee #1 put his ha... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
119,641.015 | {
"text": [
"Employee #1 was working at the site of a multifamily residential structure. He was using a shovel to dig out soil from a trench in preparation for waterproofing. The trench dimensions were 17 feet long by 80 inches wide by 72 inches deep, with a spoil pile of 4 feet placed next to the trench. The emp... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
124,340.015 | {
"text": [
"Employee #1 was operating a Superior manually guided concrete trowel machine (powered, rotating-blade type) at a commercial building job site. The machine was not equipped with the required control or switch, and it began to revolve after the employee removed both hands from the equipment handles. Th... | {
"type": "classification",
"value": [
"struck-by"
]
} |
124,254.015 | {
"text": [
"Employee #1, a foreman, and Employee #2, his helper, employed by an electrical contractor, were installing an additional series of circuits and a breaker panel at a plastics factory. The employer had agreed to do the installation while the factory was operating and electrical power was not shut off. ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
123,365.015 | {
"text": [
"Employee #1 and coworkers were installing a new water pipe in a ditch/trench. To stab the pipes together, the employees used a Lift-It continuous round sling, Model RS90W, placed around the open ball end of the pipe and attached to an excavator, although this was not the manufacturer's intended verti... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
120,430.015 | {
"text": [
"Employee #1, employed by a renovation company, was engaged in electrical work in the attic of a one-story residence. He had not turned off the electrical power. As he handled an electric wire, he was exposed to live electrical current. Employee #1 was electrocuted."
],
"children": {
"working_... | {
"type": "classification",
"value": [
"electrocution"
]
} |
122,062.015 | {
"text": [
"Employee #1, employed by a construction company, was working at the site of a new one-story commercial building. He was positioning lumber (dunnage) under a bundle of roof trusses that was being set on the ground. The bundle was 85 feet long and weighed 5,000 pounds. The spreader bar used to lift the... | {
"type": "classification",
"value": [
"struck-by"
]
} |
118,959.015 | {
"text": [
"An employee was working as a construction laborer for a firm that constructed water and sewer lines and related structures. He and two coworkers were working inside a trench. The employee was digging soil inside the excavation. He was erecting a culvert on an 11-foot-high (3.4-meter-high) vertical di... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
119,244.015 | {
"text": [
"Employee #1, employed by a concrete construction company, was working at the site of a new 15-story multifamily residential building. He was using compressed air to clean a concrete pipeline. As he attempted to disengage the fitting of the air hose reducer, which was still under pressure, the reducer... | {
"type": "classification",
"value": [
"struck-by"
]
} |
119,120.015 | {
"text": [
"An employee was working as a construction laborer for a firm that engaged in highway, street, and bridge construction. In this incident, the firm was paving a road surface. The employee was directing traffic at the entrance to and exit of a gas station. An eight-axle truck pulled up. It was pulling a... | {
"type": "classification",
"value": [
"struck-by"
]
} |
118,857.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a two-story cold storage facility. He was directing the installation of cold storage panels to a wall, which involved raising the panels 16 feet with a 55-ton Terex Crane. The panels, each weighing a... | {
"type": "classification",
"value": [
"struck-by"
]
} |
118,894.015 | {
"text": [
"Employees #1 and #2, employed by a framing contractor, were working at a construction project for a new residence. They were on the second floor deck of the residence and unstrapping a load of exterior wall panels weighing approximately 250 pounds each. A gust of wind lifted two wall panels. One stru... | {
"type": "classification",
"value": [
"struck-by"
]
} |
118,873.015 | {
"text": [
"An employee was working as an electrician for a contractor that installed electrical and other wiring. He was working in a residential condominium's electrical vault. He was installing a cable from two new transformers to a main cabinet. He had not deenergized the main electrical switch. The main cab... | {
"type": "classification",
"value": [
"electrocution"
]
} |
118,590.015 | {
"text": [
"Employee #1, employed by a construction company, was working at the site of a new golf course. He was measuring decorative rock around a lake when lightning struck. Employee #1 was electrocuted."
],
"children": {
"working_circumstances": {
"type": "extraction",
"text": [
"... | {
"type": "classification",
"value": [
"electrocution"
]
} |
118,623.015 | {
"text": [
"Employee #1, employed by an electrical services company, was repairing an electric stove inside a one-story residence. He crawled through a crawlspace to reach the metal exhaust vent/duct for the stove. The duct's casing was missing a ground wire, and the duct was energized. As Employee #1 made conta... | {
"type": "classification",
"value": [
"electrocution"
]
} |
118,869.015 | {
"text": [
"Employees #1, #2, #3, and #4, plus two additional coworkers, employed by a construction company, were constructing a new residential structure that included multiple gables. They were attempting to lift a gable wall and position it between two previously erected gables that were approximately 30 feet... | {
"type": "classification",
"value": [
"struck-by"
]
} |
118,621.015 | {
"text": [
"Employee #1 and two coworkers, employed by a construction company, were working in a wooded park. Employee #1 was driving a Yamaha Rhino 660 off-road utility vehicle on a dirt trail, and the three employees were clearing trees that had fallen on the trail. As Employee #1 drove up an incline, a tree l... | {
"type": "classification",
"value": [
"struck-by"
]
} |
117,915.015 | {
"text": [
"Employee #1, a boilermaker, and two coworkers, employed by a refractory services company, were working at a multiemployer construction project, a refinery's tank farm. They were performing maintenance and repairs to a tank's interior floating roof and bottom. They made use of an employed-designed and... | {
"type": "classification",
"value": [
"struck-by"
]
} |
117,799.015 | {
"text": [
"Employee #1 and Employee #2 were working for a pipeline construction company at a city intersection installing a steam manhole. The employees were working in a 20-foot by 20-foot trench box within a 16-foot deep excavation when the Groundforce Shorco 3M Megabrace System failed. The 3M Megabrace Syste... | {
"type": "classification",
"value": [
"struck-by"
]
} |
117,789.015 | {
"text": [
"Employee #1, employed by an electrical contractor, was engaged in rehabilitation work at a commercial building. He was using fish tape to pull electrical wire in the vicinity of unenclosed electrical cabinets. The power source had not been deenergized, and contact with 480 volts occurred, causing an ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
121,312.015 | {
"text": [
"Employee #1 and a coworker, after completing a waterproofing job at a commercial building, were riding unrestrained in the cargo area of a Ford van. The van was not equipped with rear seats and safety belts. Employee #1 was struck by unsecured work tools. He sustained a fractured spine and was paraly... | {
"type": "classification",
"value": [
"struck-by"
]
} |
117,429.015 | {
"text": [
"Employee #1 and coworkers, employed by an electrical contractor, were replacing a deteriorating utility pole and installing a new pole in a residential area. Employee #1 was working from the pole and removing wires and equipment from the pole when he cut into an energized 21 Kilovolt line. The employ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
117,191.015 | {
"text": [
"Employee #1, employed by an electrical services company, was engaged in electrical work at a multiemployer job site. After removing a 2-foot by 4-foot florescent light assembly, he was attempting to replace it with a 2-foot by 2-foot LED light assembly. He was holding non-insulated wire strippers, ap... | {
"type": "classification",
"value": [
"electrocution"
]
} |
117,574.015 | {
"text": [
"An employee was working at a residential construction site as a laborer for a landscaping company (subcontractor) loading tools into a rented Marksman trailer attached to a work truck. It was the end of the work day and a coworker (foreman) drove the truck away without checking the trailer first. The... | {
"type": "classification",
"value": [
"struck-by"
]
} |
120,362.015 | {
"text": [
"Employee #1, employed by a roofing contractor, was inspecting a residential rooftop to determine the size/scope of work. The employee contacted the energized, uninsulated electric power lines at the weatherhead and sustained an electric shock. The employee was transported to the hospital and admitted... | {
"type": "classification",
"value": [
"electrocution"
]
} |
117,060.015 | {
"text": [
"Employee #1, employed by a road and bridge construction company, was driving a water truck at a paving project. The truck brakes failed, and the employee jumped from the truck and was run over. The truck went over a cliff. The employee was transported to the hospital and admitted for treatment of fra... | {
"type": "classification",
"value": [
"struck-by"
]
} |
116,744.015 | {
"text": [
"Abstract: Employee #1, employed by an electrical services company, was working from an aerial lift and attempting to remove a grounding lead from an electrical transmission line. He used his gloved hands rather than the hot stick that had been provided. Employee #1 received a fatal electrical shock t... | {
"type": "classification",
"value": [
"electrocution"
]
} |
121,644.015 | {
"text": [
"Employees #1, #2, and #3, employed by an electrical contractor, were dismantling and removing electrically powered yard dying equipment from a closing factory. To remove large gauge copper electrical wiring from an electrical panel, Employee #1, the supervisor, used a hand-held battery powered grinde... | {
"type": "classification",
"value": [
"electrocution"
]
} |
116,832.015 | {
"text": [
"Employee #1, employed by an electrical contractor, was working at a commercial building, terminating wires in an electrical panel. The electrical panel was not de-energized. An arc flash occurred, and the employee was severely burned. The employee was transported to the hospital and admitted for trea... | {
"type": "classification",
"value": [
"electrocution"
]
} |
117,430.015 | {
"text": [
"Employee #1, employed by a road construction company, was part of a crew that had completed the day's paving work and was picking up the traffic cones. The employee attempted to climb into the pickup truck bed. The tailgate came loose and opened, and the employee fell back onto the street and was str... | {
"type": "classification",
"value": [
"struck-by"
]
} |
117,029.015 | {
"text": [
"Employee #1, employed by a plumbing contractor, was connecting a Shark Bite Coupling onto the existing release valve for a large boiler tank. Employee #1 was wearing safety glasses, protective gloves, protective shoes, and fire resistant pants. The corroded top of the boiler unit and pipe came off wh... | {
"type": "classification",
"value": [
"struck-by"
]
} |
120,287.015 | {
"text": [
"Employee #1, employed by a plumbing contractor, was engaged in maintenance and rehabilitation work at a multifamily residential building. He was cutting copper pipes to install ball valves while taking out the gate valves. The employee was operating a Ridgid Sawzall (R8642 Gen5X) cordless reciprocati... | {
"type": "classification",
"value": [
"struck-by"
]
} |
121,637.015 | {
"text": [
"An employee was installing a metal I-Beam for an automatic feed system when the safety latch on the hook failed to secure the strap. The employee incurred skull and arm fractures and was hospitalized."
],
"children": {
"working_circumstances": {
"type": "extraction",
"text": [
... | {
"type": "classification",
"value": [
"struck-by"
]
} |
116,346.015 | {
"text": [
"Employee #1 and a coworker, employed by a concrete construction company, were paving a parking lot at a multiemployer construction project. The coworker was operating a concrete pump truck, and Employee #1 was operating an end hose connected to the truck. The truck was set on ground and cribbing inca... | {
"type": "classification",
"value": [
"struck-by"
]
} |
117,233.015 | {
"text": [
"Employees #1 and #2, employed by a steel erection company, were working at grade at a multiemployer construction project, a new eight-story commercial building. They were preparing materials for erection. A pallet loaded with 144 vertical 2-inch angle iron posts, with a total weight of approximately ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
116,122.015 | {
"text": [
"Employee #1, employed by a dozer company, was working at a multiemployer construction project, an excavation landfill. He was walking toward the dozer when he was struck by falling tree branches. Emergency services transported Employee #1 to the hospital, where he died from his injuries. It was deter... | {
"type": "classification",
"value": [
"struck-by"
]
} |
115,739.015 | {
"text": [
"Employee #1, employed by a highway construction company, was using an Extech 430 Multi Meter to perform a diagnostic test on a 480 volt 50 amp circuit ITE circuit breaker that was not functioning in an emulsion tank electrical panel. When the employee touched the positive and negative test leads of t... | {
"type": "classification",
"value": [
"electrocution"
]
} |
114,588.015 | {
"text": [
"Employee #1, employed by a tile company, was engaged in interior tile work at a new residential structure. He turned on the tile grinder. Before any work began, the grinder exploded and sent shrapnel from the stone wheel into the employee's face. Employee #1, who was not wearing a face shield, sustai... | {
"type": "classification",
"value": [
"struck-by"
]
} |
114,328.015 | {
"text": [
"Employee #1 and a coworker were engaged in a cable television wiring installation at a new building. Employee #1 was working from a non-insulating bucket truck and pulling strand as his coworker worked from the ground. The strand kept getting caught in trees and vegetation. Employee #1, in frustratio... | {
"type": "classification",
"value": [
"electrocution"
]
} |
114,557.015 | {
"text": [
"Employee #1 and coworkers, employed by an electrical contractor, were removing a metal streetlight pole. As a crane lifted the pole off its bolts in the foundation plate, Employee #1 used his hands to guide and stabilize the pole. During this lifting process, the metal pole rotated and came close - a... | {
"type": "classification",
"value": [
"electrocution"
]
} |
114,510.015 | {
"text": [
"Employee #1, employed by an electrical contractor, was working at a multiemployer project, the renovation of an office building. He was taking measurements to determine the amount of wire needed to run wire into an electrical panel. When the employee attempted to replace the cover for the upper secti... | {
"type": "classification",
"value": [
"electrocution"
]
} |
111,441.015 | {
"text": [
"An employee was working for a manufacturer of sheet metal work. He was receiving a piece of metal flashing from a worker on the ground. As he was receiving the metal flashing, a gust of wind blew the flashing into an overhead power line. The line was energized at 19 kilovolts (kV). The employee susta... | {
"type": "classification",
"value": [
"electrocution"
]
} |
115,601.015 | {
"text": [
"Employee #1, a superintendent employed by a construction company, was engaged in electrical work at a seven-story hospital. He was tracing an electrical line for an x-ray \"in use\" light fixture in an above-ceiling crawlspace. He had recently tested the wiring and was aware it was energized. As the ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
108,989.015 | {
"text": [
"Employee #1, employed by an HVAC services company, was attempting to service an HVAC unit in the attic of a single family residence. He was using a 10-foot Type IA Louisville Aluminum A-frame ladder to access the attic entry, although the distance from floor to entry was 12 feet, exceeding the ladder... | {
"type": "classification",
"value": [
"fall"
]
} |
113,362.015 | {
"text": [
"Employee #1 and a Coworker, employed by a framing construction contractor, were working on the construction of three houses. The coworker, who was foreman and forklift operator, instructed Employee #1 to climb onto the JLG Telescopic Forklift, Model G10-55A, Serial Number 2015103-01, and ride it up t... | {
"type": "classification",
"value": [
"fall"
]
} |
115,727.015 | {
"text": [
"Employee #1, employed by a concrete construction company, was engaged in construction of concrete parking structures. He was handling the rubber hose, 4-5 inches in diameter, that is used to deliver concrete slurry from a concrete boom truck to the pour location. As pumping resumed after a down time,... | {
"type": "classification",
"value": [
"struck-by"
]
} |
108,784.015 | {
"text": [
"An employee was in a trench trying to fit a 2,000 pound drain pipe into a manhole guided by a track hoe. At some point, the track hoe operator released tension on the chains used to guide the pipe allowing the pipe to swing around and strike the employee. The employee received a pelvis fracture and b... | {
"type": "classification",
"value": [
"struck-by"
]
} |
108,517.015 | {
"text": [
"An employee was installing a roof on a single residential home that was being constructed. The employee had not connected his fall protection system to the roof and fell from the roof while installing the anchor plate. The employee was killed."
],
"children": {
"working_circumstances": {
... | {
"type": "classification",
"value": [
"fall"
]
} |
109,421.015 | {
"text": [
"Employee #1, employed by a concrete construction company, was working at a multiemployer construction project, a new four-story commercial building. He was working from a ladder made onsite and performing carpentry work in preparation for installing concrete forms. Employee #1 leaned back and fell fr... | {
"type": "classification",
"value": [
"fall"
]
} |
108,668.015 | {
"text": [
"Employee #1 was performing maintenance/repair activities, adding sheath to a roof during residential construction. As Employee #1 removed his O-ring clip from his harness to reach for an item, he then fell 19 feet from the second story roof to a concrete/ground landing. Employee #1 fractured his elbo... | {
"type": "classification",
"value": [
"fall"
]
} |
108,384.015 | {
"text": [
"Employee #1, employed by a construction company, was working from a 6-foot scaffold and plastering the exterior of a nine-story building as part of a multiemployer renovation project. He leaned over the scaffold's guardrail, and the scaffold tipped over and fell. Employee #1 fell, a fall height of 5.... | {
"type": "classification",
"value": [
"fall"
]
} |
108,534.015 | {
"text": [
"Employee #1 and a coworker were standing on A-frame ladders, performing exterior framing and maintenance/repair operations on single family or duplex dwellings, during residential construction. While replacing roofing shingles, on the eyebrow over the entryway, the ladder of Employee #1 somehow tippe... | {
"type": "classification",
"value": [
"fall"
]
} |
113,407.015 | {
"text": [
"Employee #1, employed by a roofing contractor, was working on the roof of a one-story commercial building. He was installing a metal frame system to the existing roof as part of a new decking installation. The employee, who was not using fall protection, fell through an unprotected skylight, a fall h... | {
"type": "classification",
"value": [
"fall"
]
} |
109,638.015 | {
"text": [
"Employee #1, a carpenter employed by a construction company, was working at a new two-story residential structure, a multiemployer construction project. He was cleaning up at the end of the workday when he fell through a stairway opening that was not properly guarded and struck his head on the concre... | {
"type": "classification",
"value": [
"fall"
]
} |
113,325.015 | {
"text": [
"Employee #1, employed by a construction contractor, was engaged in drywall installation and painting for a new two-story residential structure. He was using an unfinished stairway to move from the second floor to the first floor while carrying a tray and work materials. The employee slipped and fell ... | {
"type": "classification",
"value": [
"fall"
]
} |
109,412.015 | {
"text": [
"Employee #1, employed by a construction company, was dismantling a scaffold at the job site for a new assisted living facility. He lost balance and fell, and his abdomen was impaled on a piece of uncapped rebar. Emergency services transported the employee to the hospital, where he was treated for the... | {
"type": "classification",
"value": [
"fall"
]
} |
108,650.015 | {
"text": [
"Employee #1, a Laborer, was removing hangers from a beam within a single family home remodel in San Diego, CA. At the time of the accident, Employee #1 setup an extension ladder to continue removing the hangers. While using a pry tool, he stood approximately four feet above the cement slab. As Employ... | {
"type": "classification",
"value": [
"fall"
]
} |
112,958.015 | {
"text": [
"Employee #1, employed by a fire protection systems company, was installing pipes for a system at a customer's location. He was using a foot switch to operate a Ridgid 300 Power Drive Pipe Threading Machine and a Ridgid 918 Groover. Employee #1, who was wearing gloves, reached into the point of operat... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
108,109.015 | {
"text": [
"Employee #1, employed by a construction framing company, was working at a multiemployer construction project, a new residential building. He was installing a roof truss when the truss collapsed. Employee #1 fell, a fall height of 14 feet. He was using a personal fall arrest system, but the rope was t... | {
"type": "classification",
"value": [
"fall"
]
} |
108,128.015 | {
"text": [
"An employee was working from a wooden swing stage platform suspended scaffold while completing some masonry repairs around some window openings of a 4-story building. The platform was held in place by a synthetic rope and was raised or lowered by a block and tackle. The employee fell approximately 3 ... | {
"type": "classification",
"value": [
"fall"
]
} |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.