id float64 3.83k 163k | accident_report dict | accident_type dict |
|---|---|---|
111,539.015 | {
"text": [
"Employee #1, employed by a construction company, was working in the company welding shop. He was operating a drill press, Jet JDP-17MF SN.UNK, to place holes in the ends of 12 pieces of plate steel that measured 8 inches by 2.25 inches by 25 inches. The employee was wearing Radnor polyurethane-coated... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
108,043.015 | {
"text": [
"Employee #1, employed by a steel erection company, was installing steel decking on the second floor of a new six-story building. He unhooked his retractable fall protection lanyard, stepped on a piece of unsecured decking, slipped, and fell, a fall height of 12 feet. Emergency services transported th... | {
"type": "classification",
"value": [
"fall"
]
} |
108,024.015 | {
"text": [
"Employee #1, employed by a construction company, was operating a Luffing Boom Crane in windy conditions. He was taking wind speed readings when the luffing jib failed and the crane collapsed. Emergency services transported the employee to the hospital, where he was admitted and treated for a fracture... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
108,511.015 | {
"text": [
"Employee #1 was working on a dredging project for a power transmission line, a multiemployer construction project. He was placing pins in an uninsulated power line when he sustained an electric shock of 7,620 kilovolts. The employee was transported to the hospital, admitted, and treated for electric ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
112,053.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in the remodeling of a two-story commercial building owned by the employer. He was tasked with going up to the roof and tying tarps over the air conditioning units, which were near an unguarded skylight. The employee fell through the skylig... | {
"type": "classification",
"value": [
"fall"
]
} |
108,134.015 | {
"text": [
"Employee #1 and a coworker, employed by an insulation contractor, were installing gutters for a new residence. They were using a 6-foot ladder and a 10-foot ladder to access the roof line. As Employee #1 descended the 6-foot ladder, which was set on uneven ground, his foot caught in the third rung, a... | {
"type": "classification",
"value": [
"fall"
]
} |
108,004.015 | {
"text": [
"Employee #1, a security installation technician, was working from an 8-foot stepladder and installing interior alarm strobes throughout a building being converted to medical offices. He was working with both hands overhead and leaning backward to install electrical boxes when he lost balance, fell a ... | {
"type": "classification",
"value": [
"fall"
]
} |
110,908.015 | {
"text": [
"Employee #1 was feeding brush into a wood chipper. The chipper jammed, and without first de-energizing the machine, he tried to clear the jam with his foot. The machine amputated the employee's foot. Emergency services transported the employee to the hospital, where he was admitted and treated for th... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
110,422.015 | {
"text": [
"Employee #1, employed by a waterproofing company, was working at a one-story commercial building. He was working from a 10-foot stepladder that was in the closed position and leaning against an exterior wall. After caulking a joint, the employee began to descend the stepladder. The stepladder, which ... | {
"type": "classification",
"value": [
"fall"
]
} |
109,602.015 | {
"text": [
"Employees #1 and #2 and a coworker, employed by a construction company, were working at an excavation site associated with power transmission lines. Employees #1 and #2 were laying pea gravel and grading the 5.4 feet deep excavation in preparation for the installation of an electrical vault. They exi... | {
"type": "classification",
"value": [
"struck-by"
]
} |
108,067.015 | {
"text": [
"Employee #1 and a coworker, employed by a construction company, were engaged in forming work for a multifamily residential building. Employee #1 was helping his coworker cut rebar in a hole. Employee #1 exited the hole, lost his footing, and fell back into the hole. He landed on a piece of uncapped r... | {
"type": "classification",
"value": [
"fall"
]
} |
108,012.015 | {
"text": [
"Employee #1, employed by a construction company, was finishing a poured concrete floor for a three-story commercial building. The aluminum handle of the bull float he was using apparently came too close to overhead electrical power lines in the alley. The employee sustained an electric shock and elec... | {
"type": "classification",
"value": [
"electrocution"
]
} |
108,136.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing repair work at a commercial facility. The roof was deteriorated, and the employee fell through the roof to the concrete floor. Emergency services transported the employee to the hospital, where he was admitted and treated for a fractu... | {
"type": "classification",
"value": [
"fall"
]
} |
111,424.015 | {
"text": [
"Employee #1, a carpenter employed by a construction framing company, was working from a 6-foot ladder inside a two-story residential structure. The ladder was placed in a second floor doorway next to a floor opening that was guarded by railings. As Employee #1 attempted to install a 2 by 4 block of w... | {
"type": "classification",
"value": [
"fall"
]
} |
113,277.015 | {
"text": [
"Employee #1 and a coworker, employed by a drilling company, were drilling a water well. They were using a Speedstar Model SS25SD drill rig, a breakout rig tong, slips, and a breaker bar. Employee #1 was the helper for the coworker, who was operating the drill. In order to save time while breaking pip... | {
"type": "classification",
"value": [
"struck-by"
]
} |
112,104.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a construction project for a 63-story commercial building. He was drilling holes for setting reinforcing steel in formwork. After climbing 2 by 4s nailed into the formwork and reaching an elevation of approximately 4 feet above the floor... | {
"type": "classification",
"value": [
"fall"
]
} |
107,535.015 | {
"text": [
"Employee #1, employed by a demolition company, was demolishing a canopy over a loading dock, part of a multiemployer construction project. He had excess rope hanging from his fall protection system. The rope became caught in a skid loader, and the employee was pulled off the canopy. He fell and struc... | {
"type": "classification",
"value": [
"fall"
]
} |
108,494.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in demolition work at a one-story commercial building. He was standing on a wheeled scaffold platform and removing ductwork. The wheels were not locked. A wheel of the scaffold rolled over a hole in the floor, causing the scaffold to tip ov... | {
"type": "classification",
"value": [
"fall"
]
} |
107,642.015 | {
"text": [
"Employee #1, employed by a construction company, was repairing a hole in the roof of a three-story structure. The roof had a pitch of 2/12. He unfastened his fall protection lanyard and stepped backward. Employee #1 fell from the roof, a fall height of approximately 20 feet. Emergency services transp... | {
"type": "classification",
"value": [
"fall"
]
} |
111,214.015 | {
"text": [
"An employee was walking through the second story near an unprotected floor edge when his foot slipped through the drywall, lost his balance, and fell over the edge. The employee sustained multiple fractures and was hospitalized."
],
"children": {
"working_circumstances": {
"type": "extr... | {
"type": "classification",
"value": [
"fall"
]
} |
107,268.015 | {
"text": [
"An employee was rigging trusses onto a vehicle mounted crane to be lifted onto a residential structure under construction. After approximately 11-12 trusses were lifted onto the roof, the crane operator moved the load line to a new stack of trusses that were located near an overhead power line. The c... | {
"type": "classification",
"value": [
"electrocution"
]
} |
107,460.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in forming work at a water and sewer treatment plant. As he was climbing down a form wall, he unhooked his twin turbo lanyards, part of his fall protection system, and put weight on a support bracket. The bracket was not secure, and Employe... | {
"type": "classification",
"value": [
"fall"
]
} |
107,542.015 | {
"text": [
"Employee #1, employed by an electrical services company, was replacing a power pole and connecting lines to a new pole. He came into contact with an energized line while not wearing his PPE. The employee sustained an electric shock and burns to his back and both hands. Emergency services transported ... | {
"type": "classification",
"value": [
"electrocution"
]
} |
107,437.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in roofing work as part of a multiemployer construction project. He unhooked his lanyard from the anchor point in order to reach an area of the roof he needed to measure. Employee #1 fell, a fall height of approximately 25 feet. Emergency s... | {
"type": "classification",
"value": [
"fall"
]
} |
107,064.015 | {
"text": [
"Employee #1 and a coworker, employed by a steel erection company, were working at a multiemployer construction project. The coworker, who was tied off to a piece of unsecured formwork, leaned back and fell on top of Employee #1, who was on the ground. Emergency services transported Employee #1 to the... | {
"type": "classification",
"value": [
"struck-by"
]
} |
107,059.015 | {
"text": [
"Employee #1, employed by a concrete construction company, was walking on the ground and operating a roadway paving machine. He was struck with 7,200 volts of electricity from an electric arc that occurred when the raised bed of a tandem dump truck made contact with uninsulated overhead power lines. T... | {
"type": "classification",
"value": [
"electrocution"
]
} |
112,132.015 | {
"text": [
"Employee #1 and coworkers, employed by a construction company, were engaged in steel erection for a four-story commercial building. Employee #1 was welding a decorative structure onto a steel frame when he fell, a fall height of 20 feet, and struck a concrete deck. The employee was wearing his body h... | {
"type": "classification",
"value": [
"fall"
]
} |
108,150.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in roofing work at a two-story multifamily residential building. The roof had a 6/12 pitch. He was dismantling the old roof while not using fall protection. The employee fell, a fall height of approximately 30 feet. Emergency services trans... | {
"type": "classification",
"value": [
"fall"
]
} |
106,991.015 | {
"text": [
"Employee #1, employed by a construction company, was installing an electrical pole. He was working on the ground when an automobile, with a driver who had fallen asleep, ran through the construction barriers and struck the employee's right leg and foot. Emergency services transported Employee #1 to t... | {
"type": "classification",
"value": [
"struck-by"
]
} |
107,434.015 | {
"text": [
"Employee #1, employed by a construction company, was working inside a two-story commercial building as part of a multiemployer construction project. He was working from a 5-foot high mobile bakers scaffold and stapling insulation onto a ceiling when he leaned over the scaffold's guardrail. Employee #... | {
"type": "classification",
"value": [
"fall"
]
} |
109,418.015 | {
"text": [
"Employee #1, employed by a window company, was engaged in installation work at the renovation of a three-story commercial building. After moving material and debris from the east side of the roof to the west side, he descended a 3-foot fixed ladder. As he moved off the ladder, he stumbled and placed ... | {
"type": "classification",
"value": [
"fall"
]
} |
106,888.015 | {
"text": [
"Employee #1, employed by a construction company, was installing an aluminum sheet on top of a gas station canopy. As he handled the metal sheet, it came too close to a high voltage power line. An electric arc ensued, and Employee #1 sustained burns to his hands and an exit wound on his foot. He was t... | {
"type": "classification",
"value": [
"electrocution"
]
} |
107,590.015 | {
"text": [
"Employee #1, employed by a construction company, was painting the exterior of an existing two-story multifamily residential building. He was lying down on the roof and leaning over the edge to paint the trim when he lost his balance and fell. Emergency services transported the employee to the hospita... | {
"type": "classification",
"value": [
"fall"
]
} |
106,785.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working at a multiemployer construction project, the renovation of a commercial building. He was attempting to install a light ballast, believing the circuit he was working on was de-energized. However, the breakers had not been correctly l... | {
"type": "classification",
"value": [
"electrocution"
]
} |
106,691.015 | {
"text": [
"Employee #1 and coworkers, employed by a roofing company, were engaged in reroofing activities at a three-story commercial building. Employee #1, without using fall protection, was on the low-sloped, unguarded roof and throwing trash down to the ground. He fell, a fall height of 31 feet. Emergency se... | {
"type": "classification",
"value": [
"fall"
]
} |
106,532.015 | {
"text": [
"Employee #1 was engaged in reroofing activity at a one-story commercial building. He was moving lumber from a forklift to the roof's peak when he lost his grip on the lumber and, as a result, lost balance. Employee #1 slip down the roof and fell, a fall height of approximately 14 feet. He was wearing... | {
"type": "classification",
"value": [
"fall"
]
} |
111,796.015 | {
"text": [
"Employee #1, employed by an HVAC company, was climbing a ladder to access the roof of a two-story residence. The ladder slipped backward, and the employee fell. Emergency services transported the employee to the hospital, where he was admitted and treated for fractures to his elbow and hip. The subse... | {
"type": "classification",
"value": [
"fall"
]
} |
106,852.015 | {
"text": [
"Employee #1, employed by a construction company, was pouring concrete for a road paving project. The concrete truck struck debris in the road, causing a tire to explode. Debris from the exploding tire struck Employee #1's chest. Employee #1 was transported to the hospital, admitted, and treated for m... | {
"type": "classification",
"value": [
"struck-by"
]
} |
106,828.015 | {
"text": [
"Employee #1, a journeyman plasterer, and coworkers employed by a construction company, were engaged in the construction of a two-story school building. Employee #1 was working from the first tier of a metal scaffold with overlapping, unsecured planks. He was assisting his coworkers during masking/lat... | {
"type": "classification",
"value": [
"fall"
]
} |
106,542.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing activity at a two-story commercial building. As he secured a wet and slippery 6-inch TPO membrane over the edge of the roof deck, he fell, a fall height of 21 feet. Employee #1 at the time was working outside the warning lines and wit... | {
"type": "classification",
"value": [
"fall"
]
} |
106,537.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in roofing activity at a new one-story commercial building. He was installing metal roofing panels when he moved to a wet, shaded area. Employee #1, who was not wearing fall protection, slipped and fell from the roof. Emergency services tra... | {
"type": "classification",
"value": [
"fall"
]
} |
106,395.015 | {
"text": [
"A work-crew consisting of four employees was setting 40 ft. trusses on a new construction building with a concrete floor. The walls were framed and braced two days prior to the truss work. The crew was setting the trusses from east to west. A mobile crane lifted the trusses into place. Twelve trusses... | {
"type": "classification",
"value": [
"fall"
]
} |
106,625.015 | {
"text": [
"Employee #1, employed by a construction installations company, was working on the mezzanine level of a commercial building. He was installing metal decking when he stepped backward and fell through an undecked portion to the concrete floor, a fall height of 18 feet. The employee was transported to th... | {
"type": "classification",
"value": [
"fall"
]
} |
106,529.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in reroofing activity at a two-story commercial building. He was walking on the roof when he slipped and fell. The lifeline he was wearing for fall protection broke. Employee #1 was transported to the hospital, where he was admitted and tre... | {
"type": "classification",
"value": [
"fall"
]
} |
107,374.015 | {
"text": [
"Employee #1, employed by a home builder, was working at an existing two-story residential structure. He was on the balcony, and after removing the railings, he was labeling column trim. Employee #1, who was not using fall protection, fell from the balcony to the ground floor's stone pavers, a fall he... | {
"type": "classification",
"value": [
"fall"
]
} |
106,457.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working on electrical power lines following a power outage. The electrical utility company did not ensure that the power was switched off where the employee was working. Employee #1 received an electric shock and electrical burns. He was tr... | {
"type": "classification",
"value": [
"electrocution"
]
} |
106,271.015 | {
"text": [
"Employee #1 was engaged in roofing work at a two-story residence. He was applying shingles when he fell and struck the hard dirt surface, a fall height of 20 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for fall-related injuries. T... | {
"type": "classification",
"value": [
"fall"
]
} |
106,791.015 | {
"text": [
"An employee was working for a firm that manufactured custom architectural woodwork and millwork. He was at a jobsite. New residential construction was going up at the jobsite. The firm he worked for was there to install windows. He was a fulltime permanent employee, and he had a supervisor. The emplo... | {
"type": "classification",
"value": [
"fall"
]
} |
109,472.015 | {
"text": [
"Employee #1 and a coworker, employed by a construction company, were working at the site of a new residential structure. The coworker was operating a crane to set in place an air conditioner condenser. Employee #1 was standing nearby and waiting for the crane operation to be completed. The crane, whi... | {
"type": "classification",
"value": [
"struck-by"
]
} |
106,331.015 | {
"text": [
"Employee #1, employed by a construction company, was engaged in roofing activity at a two-story residential structure. As he installed roofing shingles, he slipped and fell, a fall height of 19 feet, and struck a concrete slab at surface. Employee #1 was using fall protection, but the anchor broke an... | {
"type": "classification",
"value": [
"fall"
]
} |
106,290.015 | {
"text": [
"Employee #1, employed by an electrical contractor, was engaged in power line work. A bucket truck was used to lift him to the power lines. Employee #1 grabbed a road phase line with his right hand while his left hand was in contact with a neutral line. He sustained an electric shock of 7,620 volts. E... | {
"type": "classification",
"value": [
"electrocution"
]
} |
106,174.015 | {
"text": [
"An employee was working for a roofing and guttering contractor. He and some coworkers were working at a residential structure (a house). They were on the roof, re-roofing the house. The roof had a 10 in 12 pitch. he had come down off the roof, due to rain that had come through the area. After the rai... | {
"type": "classification",
"value": [
"fall"
]
} |
106,097.015 | {
"text": [
"Employee #1, employed by an exterior home improvements company, was working on the roof of a two-story residential building. He was installing valley tin when he unhooked his fall protection lanyard, because the rope was caught on a roof jack. Employee #1 fell onto the valley tin and then to the grou... | {
"type": "classification",
"value": [
"fall"
]
} |
105,536.015 | {
"text": [
"Employee #1, a project foreman employed by a lathe and plaster company, was working at a two-story house that had a chimney extending above the roof. He was assigned to put a final color coat on the chimney's exterior. Employee #1 used a three-story metal scaffold with the third level approximately 2... | {
"type": "classification",
"value": [
"fall"
]
} |
106,093.015 | {
"text": [
"An employee was working for a manufacturer of ornamental and architectural metal work. He was working a powered gate opener and closer. He was replacing an existing Q019 circuit board with a new Q400 circuit board and installing an Omni Control surge suppressor. He came into contact with an electrica... | {
"type": "classification",
"value": [
"electrocution"
]
} |
106,558.015 | {
"text": [
"Employee #1 and two apprentice coworkers, employed by a construction company, were installing ductwork at a four-story commercial building. They were using two manual lifting devices to raise a 350-pound HVAC duct. They were unable to effectively secure the duct to the lifting forks. The duct began t... | {
"type": "classification",
"value": [
"fall"
]
} |
105,917.015 | {
"text": [
"Employee #1 and a coworker, employed by an electrical services company, were preparing to install electrical wiring. Employee #1 was waiting for a metal fish line that his coworker was feeding through a 3.5-foot metal conduit pipe. Employee #1 removed his left hand's glove and reached into the pipe t... | {
"type": "classification",
"value": [
"electrocution"
]
} |
106,430.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a one-story commercial building. He was moving a rolling scaffold on the existing roof, without being tied off for fall protection, when he fell through an opening in the roof to the cement floor, a ... | {
"type": "classification",
"value": [
"fall"
]
} |
105,800.015 | {
"text": [
"Employee #1, employed by a demolition company, was engaged in demolition work at a two-story commercial building. He was on the second floor and using a rivet buster to remove concrete. Employee #1 detached his safety harness before moving to a safe location. He fell, a fall height of 16 feet. Emerge... | {
"type": "classification",
"value": [
"fall"
]
} |
108,066.015 | {
"text": [
"Employee #1 and a coworker, employed by a construction company, were working at a multiemployer construction project, a development of new residences. They were engaged in erecting a wood frame wall. As they carried the frame over uneven ground, with Employee #1 walking backward, Employee #1 tripped ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
105,879.015 | {
"text": [
"Employee #1, employed by a drywall company, was working at a multiemployer construction project, a new commercial building. He was working from a scissor lift and leaning against the lift's top guardrail as he screwed drywall sheet to the ceiling. The guardrail broke and collapsed, and Employee #1 fe... | {
"type": "classification",
"value": [
"fall"
]
} |
106,017.015 | {
"text": [
"Employee #1, employed by a drywall company, was installing interior walls at a two-story multifamily residential building project. He was pushing a cart loaded with a stack of drywall when he tripped over a wire. Employee #1 fell through an unguarded opening. Emergency services were called, and Emplo... | {
"type": "classification",
"value": [
"fall"
]
} |
106,211.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a five-story multifamily residential building. He was using a cart to transport a load of unsecured 12-foot sheetrock through a hallway. The floor was not even, and one of the pieces of sheetrock fel... | {
"type": "classification",
"value": [
"struck-by"
]
} |
106,626.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a residence. He was placing material on the roof, which had a 22 degree pitch, when he tripped on loose roofing material, lost his balance, and fell, a fall height of 10 to 12 feet. Emergency services transported the employee to the hosp... | {
"type": "classification",
"value": [
"fall"
]
} |
106,165.015 | {
"text": [
"Employee #1, employed by a roofing company, was laying shingles on the roof of a two-story commercial building. He inadvertently stepped off the roof and fell, a fall height of approximately 16 feet. Emergency services transported Employee #1 to the hospital, where he was admitted and treated for mul... | {
"type": "classification",
"value": [
"fall"
]
} |
105,691.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a three-story commercial building project. He was using a hand-held Milwaukee power drill to mix concrete. When the mixing pedal came loose, the employee reached in to tighten it without first turning off the tool. The employee's left gl... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
107,348.015 | {
"text": [
"Employee #1 and a coworker, employed by a concrete construction company, were engaged in concrete formwork for a new three-story residential structure. The coworker was operating the pump truck from which concrete was being poured into a 12-foot tall aluminum form. Employee #1 was working from an ele... | {
"type": "classification",
"value": [
"fall"
]
} |
105,918.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing repair work at a two-story residence. He was on the roof and not using fall protection as he cut and replaced plywood. Employee #1 lost balance and fell, a fall height of 16 feet. Emergency services were called, and Employee #1 was tr... | {
"type": "classification",
"value": [
"fall"
]
} |
105,784.015 | {
"text": [
"Employee #1 was working at the site of a two-story residential construction project. He was erecting a 2nd floor exterior wood-framed wall measuring 10 feet by 20 feet when a gust of wind blew the wall over. As the wall fell, it struck Employee #1. Emergency services were called, and Employee #1 was ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
105,640.015 | {
"text": [
"Employee #1, employed by a heating and air conditioning service, was replacing a furnace system at a residential property. Prior to beginning work, he did not shut off the power to the breaker. The employee made contact with an energized metal-clad cable and sustained an electric shock to his left ar... | {
"type": "classification",
"value": [
"electrocution"
]
} |
105,632.015 | {
"text": [
"Employee #1, employed by an electrical services company, was working on the roof of a one-story residence. He was scouting for appropriate locations to install solar panel conduit. Employee #1, who was not using fall protection, fell from the roof, a fall height of approximately 16.7 feet. He require... | {
"type": "classification",
"value": [
"fall"
]
} |
105,665.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a multiemployer construction project, a three-story multifamily residential building. He was holding a plank and walking on the second-story landing, from which a guardrail had been removed. Employee #1 fell off the landing, a fall heigh... | {
"type": "classification",
"value": [
"fall"
]
} |
107,073.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a new two-story multifamily residential structure, a multiemployer construction project. He was engaged in concrete forming work. Employee #1 climbed an extension ladder to secure a 2 by 4 panel with a hammer. The ladder was not properly... | {
"type": "classification",
"value": [
"fall"
]
} |
105,992.015 | {
"text": [
"Employee #1, employed by a construction company, was installing ceramic roofing tiles to the roof of a new one-story residence as part of a multiemployer construction project. The portable ladder from which he was working was not positioned securely. The ladder shifted, and Employee #1 fell to the co... | {
"type": "classification",
"value": [
"fall"
]
} |
109,437.015 | {
"text": [
"Employee #1 and his supervisor, employed by a roofing company, were among multiple employees engaged in reroofing activity on the roof of a two-story residential structure. Employee #1, who was not using fall protection, was receiving instructions from the supervisor. When Employee #1 moved to reposi... | {
"type": "classification",
"value": [
"fall"
]
} |
129,826.015 | {
"text": [
"Employee #1 and a coworker, employed by a drywall construction company, were working at a multiemployer construction site, a four-story commercial building. They were straddling the gap between a wall opening and a site-built wooden trash box that measured approximately 9 feet by 4.33 feet by 3.67 fe... | {
"type": "classification",
"value": [
"fall"
]
} |
107,411.015 | {
"text": [
"Employee #1, employed by a power line construction company, was operating a battery operated, hydraulic, crimping tool to install clips on an underground cable inside a pad-mounted transformer. The crimping tool was not insulated. The crimping tool cut through a 120-volt cable, which caused an electr... | {
"type": "classification",
"value": [
"electrocution"
]
} |
105,317.015 | {
"text": [
"Employee #1, employed by a home builder, was preparing to work on the roof of a two-story residential structure. He stepped onto the roof, which had a 3.5:12 pitch, intending to install toe boards for fall protection. Frost had created a slippery surface on the roof decking, and Employee #1 slipped a... | {
"type": "classification",
"value": [
"fall"
]
} |
105,254.015 | {
"text": [
"Employee #1, employed by a construction company, was operating an Allen HED Screed Machine to finish a bridge's concrete deck, part of a multiemployer construction project. He received approximately 15 seconds of training on the machine controls, provided by the supervisor prior to the assignment. Em... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
105,190.015 | {
"text": [
"Employee #1 and a coworker, employed by a construction company, were installing new water mains at a hospital construction project. Employee #1 was operating a skid steer loader and his coworker was operating a hydraulic excavator. As Employee #1 attempted to hook a chain and attachments to the excav... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
105,197.015 | {
"text": [
"Employee #1, employed by a concrete contractor, was working at a multiemployer construction project, a six-story multifamily residential structure. He was cutting an opening in a concrete wall. The floor next to the wall opening became wet and slippery due to the wet concrete cutting process. As Empl... | {
"type": "classification",
"value": [
"fall"
]
} |
110,178.015 | {
"text": [
"Employee #1 and his coworker, employed by a mechanical contractor, were working at a multiemployer construction project. Employee #1 was cleaning an inclined glass conveyor that was not locked out/tagged out and that was powered on. He was using a bar to clean the scraper underneath the conveyor. The... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
105,869.015 | {
"text": [
"Employee #1 and two coworkers, employed by a home builder, were working at a multiemployer construction project, a residential building. They were carrying a granite slab into the building when Employee #1 tripped on a piece of scaffolding on the garage floor. As Employee #1 fell, the granite fell on... | {
"type": "classification",
"value": [
"struck-by"
]
} |
105,014.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing repair and maintenance work at a one-story multifamily residence. The roof had an 8:12 pitch, and its surface was covered with 30-pound felt paper still moist from the morning dew. Employee #1's assigned task was to install a metal no... | {
"type": "classification",
"value": [
"fall"
]
} |
105,040.015 | {
"text": [
"Employee #1 and a coworker, employed by an electrical services company, were engaged in installation work inside a 24-foot building. They were pulling Cat 5E data cable from the top of a large walk-in freezer and attaching J-hooks. The employees were not using fall protection. Employee #1 fell, a fal... | {
"type": "classification",
"value": [
"fall"
]
} |
106,289.015 | {
"text": [
"Employee #1, employed by an electrical services company, was conducting testing of electrical wiring at a multiemployer construction project, a 28-story commercial building. Employee #1 sustained an electric shock. Emergency services were called, and Employee #1 was transported to the hospital, where... | {
"type": "classification",
"value": [
"electrocution"
]
} |
106,181.015 | {
"text": [
"Employee #1, employed by a heating and air conditioning company, was installing equipment on the roof of a two-story residential building. As he climbed an 8-foot Gorilla dual purpose extension ladder, he slipped on the ladder's rungs, which were slippery from the morning dew. Employee #1 fell, a fal... | {
"type": "classification",
"value": [
"fall"
]
} |
104,832.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in repairing the roof of a one-story building. As he walked on the roof, a weak part of the surface collapsed and he fell through, a fall height of 15 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was ... | {
"type": "classification",
"value": [
"fall"
]
} |
105,063.015 | {
"text": [
"Employee #1, employed by a construction framing company, was working at a multiemployer construction project, a four-story hotel. He was working on the roof when a guardrail system failed and he fell. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and... | {
"type": "classification",
"value": [
"fall"
]
} |
104,749.015 | {
"text": [
"Employee #1, employed by a drilling construction company, was operating an Akkerman Guided Boring Machine Model 308A with jacking 10-inch diameter steel casing. As he was removing steel wedges used to connect casing, he bumped and activated the thrust control lever. His head was caught between the ma... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
108,476.015 | {
"text": [
"An employee was working on a corner of a patio of a two story, single residential home and was installing several blocks on the framed patio structure. He had installed one or two blocks before walking away for a break. The employee returned and stepped on a block that had not been secured, lost his ... | {
"type": "classification",
"value": [
"fall"
]
} |
107,240.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a private residence. He used a pressure washer to wash the driveway. The homeowner then asked Employee #1 to wash the windows and provided a 14-foot aluminum straight ladder. As Employee #1 worked from the ladder, water from the pressure... | {
"type": "classification",
"value": [
"fall"
]
} |
109,218.015 | {
"text": [
"Employee #1, a rigger employed by a construction framing company, was working at a multiemployer construction project, a seven-story multifamily residential building. He was on the fifth floor and unloading a bundle of two by four lumber. As he turned away from the load, he walked over a floor shaft ... | {
"type": "classification",
"value": [
"fall"
]
} |
105,070.015 | {
"text": [
"Employee #1, employed by a roofing company, was engaged in roofing activity at a one-story manufacturing facility. As he crossed the roof placing material to be installed, he fell through an unguarded skylight, a fall height of 17.8 feet. Emergency services were called, and Employee #1 was transporte... | {
"type": "classification",
"value": [
"fall"
]
} |
105,617.015 | {
"text": [
"Employee #1, employed by a construction company, was working at a one-story commercial building. He was working from an 8-foot square concrete slab elevated approximately 9.5 feet above the lower level and installing a water softening system. As he attempted to climb down using a 24-foot fiberglass l... | {
"type": "classification",
"value": [
"fall"
]
} |
104,489.015 | {
"text": [
"Employee #1 and a coworker, employed by a construction company, were working at a multiemployer construction project, a one-story commercial building. Employee #1 was working from a Werner Type 1 aluminum extension ladder, the top of which rested against a roof truss approximately 14 feet above the s... | {
"type": "classification",
"value": [
"fall"
]
} |
104,466.015 | {
"text": [
"An employee was using the bucket of an excavator to disassemble a trench box. After instructing workers to remove the pins from the trench box and then to stand back, the employee maneuvered the bucket of the excavator to grab hold of the trench box side shield to release its spreaders. All the side ... | {
"type": "classification",
"value": [
"struck-by"
]
} |
104,532.015 | {
"text": [
"Employee #1, employed by an insulation company, was working at a multiemployer construction project, a new residential townhouse. He was standing on drywall and using it as a working surface as he installed insulation. The drywall broke, and Employee #1 fell, a fall height of approximately 7 feet. As... | {
"type": "classification",
"value": [
"fall"
]
} |
104,663.015 | {
"text": [
"Employee #1, employed by a building maintenance company, was engaged in painting activity at a residential building. He was working from an extension ladder when the ladder's feet, which were set on a wet stone patio, slid backwards. Employee #1 fell, a fall height of 9.25 feet, and struck the stone ... | {
"type": "classification",
"value": [
"fall"
]
} |
104,348.015 | {
"text": [
"An employee was installing helical piers to secure a foundation on a new construction site. The employee was outside the skid steer (track loader) cab. The equipment was on. A hydraulic hose that operates the skid steer helical pier driver attachment was wrapped around the right joystick of the skid ... | {
"type": "classification",
"value": [
"caught-in/between"
]
} |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.