| // clk_out must be more than twice as fast as the gate_in rate. | |
| module data_xdomain #( | |
| parameter size=16 | |
| ) ( | |
| input clk_in, | |
| input gate_in, | |
| input [size-1:0] data_in, | |
| input clk_out, | |
| output gate_out, | |
| output [size-1:0] data_out | |
| ); | |
| reg [size-1:0] data_latch=0; | |
| always @(posedge clk_in) if (gate_in) data_latch <= data_in; | |
| wire gate_x; | |
| flag_xdomain foo( | |
| .clk1(clk_in), .flagin_clk1(gate_in), | |
| .clk2(clk_out), .flagout_clk2(gate_x)); | |
| wire [size-1:0] data_pipe; | |
| // Using data_latch directly is OK by Vivado, but simulation shows | |
| // that doing so markedly reduces the available throughput. | |
| assign data_pipe = data_latch; | |
| // Vivado complains bitterly about this version, calling it | |
| // CDC-4 Critical. See UG906 for discussion. | |
| reg_tech_cdc #(.POST_STAGES(0)) rtc[size-1:0] (.C(clk_out), | |
| .I(data_latch), .O(data_pipe)); | |
| // CDC-15 Warning Clock enable controlled CDC structure detected | |
| // "The CDC engine only checks that [CE] is [valid in clk_out]. | |
| // Also, you are responsible for constraining the latency from the | |
| // [clk_in] domain to [clk_out latch input], which is usually done | |
| // by a set_max_delay -datapath_only constraint." | |
| reg [size-1:0] data_out_r=0; | |
| reg gate_out_r=0; | |
| always @(posedge clk_out) begin | |
| if (gate_x) data_out_r <= data_pipe; | |
| gate_out_r <= gate_x; | |
| end | |
| assign data_out = data_out_r; | |
| assign gate_out = gate_out_r; | |
| endmodule | |