new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 19

HACK: Learning a Parametric Head and Neck Model for High-fidelity Animation

Significant advancements have been made in developing parametric models for digital humans, with various approaches concentrating on parts such as the human body, hand, or face. Nevertheless, connectors such as the neck have been overlooked in these models, with rich anatomical priors often unutilized. In this paper, we introduce HACK (Head-And-neCK), a novel parametric model for constructing the head and cervical region of digital humans. Our model seeks to disentangle the full spectrum of neck and larynx motions, facial expressions, and appearance variations, providing personalized and anatomically consistent controls, particularly for the neck regions. To build our HACK model, we acquire a comprehensive multi-modal dataset of the head and neck under various facial expressions. We employ a 3D ultrasound imaging scheme to extract the inner biomechanical structures, namely the precise 3D rotation information of the seven vertebrae of the cervical spine. We then adopt a multi-view photometric approach to capture the geometry and physically-based textures of diverse subjects, who exhibit a diverse range of static expressions as well as sequential head-and-neck movements. Using the multi-modal dataset, we train the parametric HACK model by separating the 3D head and neck depiction into various shape, pose, expression, and larynx blendshapes from the neutral expression and the rest skeletal pose. We adopt an anatomically-consistent skeletal design for the cervical region, and the expression is linked to facial action units for artist-friendly controls. HACK addresses the head and neck as a unified entity, offering more accurate and expressive controls, with a new level of realism, particularly for the neck regions. This approach has significant benefits for numerous applications and enables inter-correlation analysis between head and neck for fine-grained motion synthesis and transfer.

  • 10 authors
·
May 8, 2023

Why Registration Quality Matters: Enhancing sCT Synthesis with IMPACT-Based Registration

We participated in the SynthRAD2025 challenge (Tasks 1 and 2) with a unified pipeline for synthetic CT (sCT) generation from MRI and CBCT, implemented using the KonfAI framework. Our model is a 2.5D U-Net++ with a ResNet-34 encoder, trained jointly across anatomical regions and fine-tuned per region. The loss function combined pixel-wise L1 loss with IMPACT-Synth, a perceptual loss derived from SAM and TotalSegmentator to enhance structural fidelity. Training was performed using AdamW (initial learning rate = 0.001, halved every 25k steps) on patch-based, normalized, body-masked inputs (320x320 for MRI, 256x256 for CBCT), with random flipping as the only augmentation. No post-processing was applied. Final predictions leveraged test-time augmentation and five-fold ensembling. The best model was selected based on validation MAE. Two registration strategies were evaluated: (i) Elastix with mutual information, consistent with the challenge pipeline, and (ii) IMPACT, a feature-based similarity metric leveraging pretrained segmentation networks. On the local test sets, IMPACT-based registration achieved more accurate and anatomically consistent alignments than mutual-information-based registration, resulting in improved sCT synthesis with lower MAE and more realistic anatomical structures. On the public validation set, however, models trained with Elastix-aligned data achieved higher scores, reflecting a registration bias favoring alignment strategies consistent with the evaluation pipeline. This highlights how registration errors can propagate into supervised learning, influencing both training and evaluation, and potentially inflating performance metrics at the expense of anatomical fidelity. By promoting anatomically consistent alignment, IMPACT helps mitigate this bias and supports the development of more robust and generalizable sCT synthesis models.

  • 4 authors
·
Oct 24, 2025

SKEL-CF: Coarse-to-Fine Biomechanical Skeleton and Surface Mesh Recovery

Parametric 3D human models such as SMPL have driven significant advances in human pose and shape estimation, yet their simplified kinematics limit biomechanical realism. The recently proposed SKEL model addresses this limitation by re-rigging SMPL with an anatomically accurate skeleton. However, estimating SKEL parameters directly remains challenging due to limited training data, perspective ambiguities, and the inherent complexity of human articulation. We introduce SKEL-CF, a coarse-to-fine framework for SKEL parameter estimation. SKEL-CF employs a transformer-based encoder-decoder architecture, where the encoder predicts coarse camera and SKEL parameters, and the decoder progressively refines them in successive layers. To ensure anatomically consistent supervision, we convert the existing SMPL-based dataset 4DHuman into a SKEL-aligned version, 4DHuman-SKEL, providing high-quality training data for SKEL estimation. In addition, to mitigate depth and scale ambiguities, we explicitly incorporate camera modeling into the SKEL-CF pipeline and demonstrate its importance across diverse viewpoints. Extensive experiments validate the effectiveness of the proposed design. On the challenging MOYO dataset, SKEL-CF achieves 85.0 MPJPE / 51.4 PA-MPJPE, significantly outperforming the previous SKEL-based state-of-the-art HSMR (104.5 / 79.6). These results establish SKEL-CF as a scalable and anatomically faithful framework for human motion analysis, bridging the gap between computer vision and biomechanics. Our implementation is available on the project page: https://pokerman8.github.io/SKEL-CF/.

  • 9 authors
·
Nov 25, 2025

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatially coherent geometric discrepancies that act as structured label noise. We investigate how this registration-induced bias affects supervised MRI-to-CT and CBCT-to-CT synthesis on 1,784 paired patients covering five anatomical regions. Voxel-wise scores strongly depend on the consistency between the registration used to build the training targets and the one used for evaluation: models score best when both conventions match, showing that networks partly learn the geometric convention of the registration pipeline and that standard metrics reward it. Training on more anatomically consistent registrations reduces prediction variability and improves out-of-distribution robustness, and CT-only controls show that registration alone produces metric errors in the range of top challenge submissions. To mitigate the limits of voxel-wise supervision, we introduce a perceptual loss computed in the feature space of a pretrained Segment Anything encoder. Compared with MAE-only and VGG-based objectives, it improves downstream segmentation and yields sharper, more structurally coherent sCT. Perceptual and voxel-wise metrics disagree under imperfect alignment and agree when the evaluation geometry is reliable. These results identify registration-induced bias as a central confounder in supervised sCT generation and argue for complementing voxel-wise agreement with anatomy-oriented evaluation criteria.

  • 5 authors
·
Sep 23

Radiology Report Conditional 3D CT Generation with Multi Encoder Latent diffusion Model

Text to image latent diffusion models have recently advanced medical image synthesis, but applications to 3D CT generation remain limited. Existing approaches rely on simplified prompts, neglecting the rich semantic detail in full radiology reports, which reduces text image alignment and clinical fidelity. We propose Report2CT, a radiology report conditional latent diffusion framework for synthesizing 3D chest CT volumes directly from free text radiology reports, incorporating both findings and impression sections using multiple text encoder. Report2CT integrates three pretrained medical text encoders (BiomedVLP CXR BERT, MedEmbed, and ClinicalBERT) to capture nuanced clinical context. Radiology reports and voxel spacing information condition a 3D latent diffusion model trained on 20000 CT volumes from the CT RATE dataset. Model performance was evaluated using Frechet Inception Distance (FID) for real synthetic distributional similarity and CLIP based metrics for semantic alignment, with additional qualitative and quantitative comparisons against GenerateCT model. Report2CT generated anatomically consistent CT volumes with excellent visual quality and text image alignment. Multi encoder conditioning improved CLIP scores, indicating stronger preservation of fine grained clinical details in the free text radiology reports. Classifier free guidance further enhanced alignment with only a minor trade off in FID. We ranked first in the VLM3D Challenge at MICCAI 2025 on Text Conditional CT Generation and achieved state of the art performance across all evaluation metrics. By leveraging complete radiology reports and multi encoder text conditioning, Report2CT advances 3D CT synthesis, producing clinically faithful and high quality synthetic data.

  • 5 authors
·
Sep 17, 2025

XAI-CLIP: ROI-Guided Perturbation Framework for Explainable Medical Image Segmentation in Multimodal Vision-Language Models

Medical image segmentation is a critical component of clinical workflows, enabling accurate diagnosis, treatment planning, and disease monitoring. However, despite the superior performance of transformer-based models over convolutional architectures, their limited interpretability remains a major obstacle to clinical trust and deployment. Existing explainable artificial intelligence (XAI) techniques, including gradient-based saliency methods and perturbation-based approaches, are often computationally expensive, require numerous forward passes, and frequently produce noisy or anatomically irrelevant explanations. To address these limitations, we propose XAI-CLIP, an ROI-guided perturbation framework that leverages multimodal vision-language model embeddings to localize clinically meaningful anatomical regions and guide the explanation process. By integrating language-informed region localization with medical image segmentation and applying targeted, region-aware perturbations, the proposed method generates clearer, boundary-aware saliency maps while substantially reducing computational overhead. Experiments conducted on the FLARE22 and CHAOS datasets demonstrate that XAI-CLIP achieves up to a 60\% reduction in runtime, a 44.6\% improvement in dice score, and a 96.7\% increase in Intersection-over-Union for occlusion-based explanations compared to conventional perturbation methods. Qualitative results further confirm cleaner and more anatomically consistent attribution maps with fewer artifacts, highlighting that the incorporation of multimodal vision-language representations into perturbation-based XAI frameworks significantly enhances both interpretability and efficiency, thereby enabling transparent and clinically deployable medical image segmentation systems.

  • 5 authors
·
Jan 31

RLHND: Video Foundation Models as Physically Grounded Hand Trackers for Robot Learning

Recently, approaches that leverage human video datasets for robot policy training have become increasingly prevalent. However, most existing hand trackers regress pose from cropped frames with limited priors on hand motion and object interaction, resulting in inaccurate and physically inconsistent estimates. Moreover, the lack of physical cues, e.g., contact and force, limits the use of human videos for robot policy training. To this end, we propose RLHND, a video foundation model-based hand tracking model that jointly estimates hand pose and realistic tactile information from monocular egocentric videos. RLHND turns the pre-trained Cosmos 3 video diffusion backbone into a deterministic clip-level feature extractor via clean-latent conditioning, carrying its learned priors on hand motion and hand-object interaction into tracking. For pose estimation, RLHND (i) predicts hand poses with anatomically plausible joint angles and (ii) enables optional conditioning on the shape parameter to maintain consistent hand shape within the same video and even across videos recorded by the same actor. For tactile estimation, a separate tactile expert stream, trained with the pose stream frozen, predicts dense contact and force over the hand surface. We further adopt LBS-based feature spreading to enable vertex-wise feature extraction without costly per-vertex attention. RLHND achieves state-of-the-art performance across various benchmark datasets for pose estimation, while also achieving state-of-the-art performance in contact and force estimation. Moreover, we demonstrate the utility of RLHND for robot learning through retargeting results and real-world robot experiments. The code will be publicly available at https://seungjun-moon.github.io/rlhnd/.

RLWRLD RLWRLD
·
Oct 6 1

SIMSPINE: A Biomechanics-Aware Simulation Framework for 3D Spine Motion Annotation and Benchmarking

Modeling spinal motion is fundamental to understanding human biomechanics, yet remains underexplored in computer vision due to the spine's complex multi-joint kinematics and the lack of large-scale 3D annotations. We present a biomechanics-aware keypoint simulation framework that augments existing human pose datasets with anatomically consistent 3D spinal keypoints derived from musculoskeletal modeling. Using this framework, we create the first open dataset, named SIMSPINE, which provides sparse vertebra-level 3D spinal annotations for natural full-body motions in indoor multi-camera capture without external restraints. With 2.14 million frames, this enables data-driven learning of vertebral kinematics from subtle posture variations and bridges the gap between musculoskeletal simulation and computer vision. In addition, we release pretrained baselines covering fine-tuned 2D detectors, monocular 3D pose lifting models, and multi-view reconstruction pipelines, establishing a unified benchmark for biomechanically valid spine motion estimation. Specifically, our 2D spine baselines improve the state-of-the-art from 0.63 to 0.80 AUC in controlled environments, and from 0.91 to 0.93 AP for in-the-wild spine tracking. Together, the simulation framework and SIMSPINE dataset advance research in vision-based biomechanics, motion analysis, and digital human modeling by enabling reproducible, anatomically grounded 3D spine estimation under natural conditions.

Anatomy-Guided Residual Motion Diffusion for Controllable 4D Cardiac MRI Synthesis

Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation. A semi-supervised variational autoencoder learns a compact latent representation of anatomical volumes while jointly predicting aligned segmentation masks in a unified framework. Anatomical structure is then disentangled from temporal dynamics through a cascaded latent diffusion model (LDM). A static LDM generates subject-specific anatomy conditioned on clinical priors (diagnosis and volumes measures) and a subsequent motion LDM estimates residual latent motions, ensuring strict temporal coherence across the 4D sequence. The proposed approach was evaluated on cine cardiac MRI as a representative 4D imaging application. Experiments across multiple datasets demonstrate high controllability of static anatomy (Pearson r > 0.8) and strong temporal coherence (FVD = 288.08). In cross-vendor generalization experiments, augmenting training sets with synthetic 4D sequences significantly improves downstream segmentation performance. Using nnU-Net, the proposed augmentation strategy improves the average Dice score by 1.4% and reduces the Hausdorff Distance by 3.0mm compared to training on real data alone, for the left ventricle, Dice improves by 2.8% with a 5.4mm reduction in boundary error. Overall, this framework provides a scalable and controllable solution for 4D medical image synthesis, supporting the development of more robust models with limited annotations and cross-vendor variability. Code available on https://github.com/cyiheng/4DCardiacMRISynthesis.

  • 5 authors
·
Jun 24

Attention-ResUNet for Automated Fetal Head Segmentation

Automated fetal head segmentation in ultrasound images is critical for accurate biometric measurements in prenatal care. While existing deep learning approaches have achieved a reasonable performance, they struggle with issues like low contrast, noise, and complex anatomical boundaries which are inherent to ultrasound imaging. This paper presents Attention-ResUNet. It is a novel architecture that synergistically combines residual learning with multi-scale attention mechanisms in order to achieve enhanced fetal head segmentation. Our approach integrates attention gates at four decoder levels to focus selectively on anatomically relevant regions while suppressing the background noise, and complemented by residual connections which facilitates gradient flow and feature reuse. Extensive evaluation on the HC18 Challenge dataset where n = 200 demonstrates that Attention ResUNet achieves a superior performance with a mean Dice score of 99.30 +/- 0.14% against similar architectures. It significantly outperforms five baseline architectures including ResUNet (99.26%), Attention U-Net (98.79%), Swin U-Net (98.60%), Standard U-Net (98.58%), and U-Net++ (97.46%). Through statistical analysis we confirm highly significant improvements (p < 0.001) with effect sizes that range from 0.230 to 13.159 (Cohen's d). Using Saliency map analysis, we reveal that our architecture produces highly concentrated, anatomically consistent activation patterns, which demonstrate an enhanced interpretability which is crucial for clinical deployment. The proposed method establishes a new state of the art performance for automated fetal head segmentation whilst maintaining computational efficiency with 14.7M parameters and a 45 GFLOPs inference cost. Code repository: https://github.com/Ammar-ss

  • 2 authors
·
Apr 20

CheXanatomy: Anatomy-Aware Vision-Language Modeling for Chest Radiographs

Vision-language models (VLMs) pretrained on large-scale image-text pairs demonstrate strong image-level understanding, but are primarily optimized for global alignment and do not explicitly encode fine-grained anatomical structure, limiting their suitability for spatially precise tasks such as segmentation. We introduce CheXanatomy, a framework that integrates explicit anatomical knowledge into a pretrained VLM through autoregressive token-space supervision. Instead of adding task-specific decoder heads, the model is trained to generate anatomical segmentation masks via next-token prediction. To enable scalable supervision, we synthesize realistic chest radiographs from CT volumes and forward-project CT segmentation labels to obtain anatomically consistent 2D masks. We evaluate the approach on synthetic and real chest radiographs against a U-Net baseline, including ablations on model scale, input resolution, and vision encoder fine-tuning. Autoregressive anatomical supervision achieves performance comparable to specialized convolutional models in-distribution and demonstrates improved geometric robustness under domain shift to real CXR data. In addition, anatomy-pretrained models exhibit improved sample efficiency when adapting to novel localization tasks under limited supervision. Larger models and higher input image resolution improve performance, while vision encoder fine-tuning has limited effect. These results show that embedding anatomical structure directly into the generative objective promotes spatially grounded representations and supports anatomy-aware medical vision-language modeling.

  • 3 authors
·
Jun 24

A Deep-Learning Approach For Direct Whole-Heart Mesh Reconstruction

Automated construction of surface geometries of cardiac structures from volumetric medical images is important for a number of clinical applications. While deep-learning-based approaches have demonstrated promising reconstruction precision, these approaches have mostly focused on voxel-wise segmentation followed by surface reconstruction and post-processing techniques. However, such approaches suffer from a number of limitations including disconnected regions or incorrect surface topology due to erroneous segmentation and stair-case artifacts due to limited segmentation resolution. We propose a novel deep-learning-based approach that directly predicts whole heart surface meshes from volumetric CT and MR image data. Our approach leverages a graph convolutional neural network to predict deformation on mesh vertices from a pre-defined mesh template to reconstruct multiple anatomical structures in a 3D image volume. Our method demonstrated promising performance of generating whole heart reconstructions with as good or better accuracy than prior deep-learning-based methods on both CT and MR data. Furthermore, by deforming a template mesh, our method can generate whole heart geometries with better anatomical consistency and produce high-resolution geometries from lower resolution input image data. Our method was also able to produce temporally consistent surface mesh predictions for heart motion from CT or MR cine sequences, and therefore can potentially be applied for efficiently constructing 4D whole heart dynamics. Our code and pre-trained networks are available at https://github.com/fkong7/MeshDeformNet

  • 3 authors
·
Sep 12, 2021

Better Tokens for Better 3D: Advancing Vision-Language Modeling in 3D Medical Imaging

Recent progress in vision-language modeling for 3D medical imaging has been fueled by large-scale computed tomography (CT) corpora with paired free-text reports, stronger architectures, and powerful pretrained models. This has enabled applications such as automated report generation and text-conditioned 3D image synthesis. Yet, current approaches struggle with high-resolution, long-sequence volumes: contrastive pretraining often yields vision encoders that are misaligned with clinical language, and slice-wise tokenization blurs fine anatomy, reducing diagnostic performance on downstream tasks. We introduce BTB3D (Better Tokens for Better 3D), a causal convolutional encoder-decoder that unifies 2D and 3D training and inference while producing compact, frequency-aware volumetric tokens. A three-stage training curriculum enables (i) local reconstruction, (ii) overlapping-window tiling, and (iii) long-context decoder refinement, during which the model learns from short slice excerpts yet generalizes to scans exceeding 300 slices without additional memory overhead. BTB3D sets a new state-of-the-art on two key tasks: it improves BLEU scores and increases clinical F1 by 40% over CT2Rep, CT-CHAT, and Merlin for report generation; and it reduces FID by 75% and halves FVD compared to GenerateCT and MedSyn for text-to-CT synthesis, producing anatomically consistent 512*512*241 volumes. These results confirm that precise three-dimensional tokenization, rather than larger language backbones alone, is essential for scalable vision-language modeling in 3D medical imaging. The codebase is available at: https://github.com/ibrahimethemhamamci/BTB3D

  • 10 authors
·
Oct 23, 2025

SCULPTOR: Skeleton-Consistent Face Creation Using a Learned Parametric Generator

Recent years have seen growing interest in 3D human faces modelling due to its wide applications in digital human, character generation and animation. Existing approaches overwhelmingly emphasized on modeling the exterior shapes, textures and skin properties of faces, ignoring the inherent correlation between inner skeletal structures and appearance. In this paper, we present SCULPTOR, 3D face creations with Skeleton Consistency Using a Learned Parametric facial generaTOR, aiming to facilitate easy creation of both anatomically correct and visually convincing face models via a hybrid parametric-physical representation. At the core of SCULPTOR is LUCY, the first large-scale shape-skeleton face dataset in collaboration with plastic surgeons. Named after the fossils of one of the oldest known human ancestors, our LUCY dataset contains high-quality Computed Tomography (CT) scans of the complete human head before and after orthognathic surgeries, critical for evaluating surgery results. LUCY consists of 144 scans of 72 subjects (31 male and 41 female) where each subject has two CT scans taken pre- and post-orthognathic operations. Based on our LUCY dataset, we learn a novel skeleton consistent parametric facial generator, SCULPTOR, which can create the unique and nuanced facial features that help define a character and at the same time maintain physiological soundness. Our SCULPTOR jointly models the skull, face geometry and face appearance under a unified data-driven framework, by separating the depiction of a 3D face into shape blend shape, pose blend shape and facial expression blend shape. SCULPTOR preserves both anatomic correctness and visual realism in facial generation tasks compared with existing methods. Finally, we showcase the robustness and effectiveness of SCULPTOR in various fancy applications unseen before.

  • 11 authors
·
Sep 14, 2022

A 3D Cross-modal Keypoint Descriptor for MR-US Matching and Registration

Intraoperative registration of real-time ultrasound (iUS) to preoperative Magnetic Resonance Imaging (MRI) remains an unsolved problem due to severe modality-specific differences in appearance, resolution, and field-of-view. To address this, we propose a novel 3D cross-modal keypoint descriptor for MRI-iUS matching and registration. Our approach employs a patient-specific matching-by-synthesis approach, generating synthetic iUS volumes from preoperative MRI. This enables supervised contrastive training to learn a shared descriptor space. A probabilistic keypoint detection strategy is then employed to identify anatomically salient and modality-consistent locations. During training, a curriculum-based triplet loss with dynamic hard negative mining is used to learn descriptors that are i) robust to iUS artifacts such as speckle noise and limited coverage, and ii) rotation-invariant. At inference, the method detects keypoints in MR and real iUS images and identifies sparse matches, which are then used to perform rigid registration. Our approach is evaluated using 3D MRI-iUS pairs from the ReMIND dataset. Experiments show that our approach outperforms state-of-the-art keypoint matching methods across 11 patients, with an average precision of 69.8%. For image registration, our method achieves a competitive mean Target Registration Error of 2.39 mm on the ReMIND2Reg benchmark. Compared to existing iUS-MR registration approaches, our framework is interpretable, requires no manual initialization, and shows robustness to iUS field-of-view variation. Code, data and model weights are available at https://github.com/morozovdd/CrossKEY.

  • 3 authors
·
Mar 31

Skill-Evolving Grounded Reasoning for Free-Text Promptable 3D Medical Image Segmentation

Free-text promptable 3D medical image segmentation offers an intuitive and clinically flexible interaction paradigm. However, current methods are highly sensitive to linguistic variability: minor changes in phrasing can cause substantial performance degradation despite identical clinical intent. Existing approaches attempt to improve robustness through stronger vision-language fusion or larger vocabularies, yet they lack mechanisms to consistently align ambiguous free-form expressions with anatomically grounded representations. We propose Skill-Evolving grounded Reasoning (SEER), a novel framework for free-text promptable 3D medical image segmentation that explicitly bridges linguistic variability and anatomical precision through a reasoning-driven design. First, we curate the SEER-Trace dataset, which pairs raw clinical requests with image-grounded, skill-tagged reasoning traces, establishing a reproducible benchmark. Second, SEER constructs an evidence-aligned target representation via a vision-language reasoning chain that verifies clinical intent against image-derived anatomical evidence, thereby enforcing semantic consistency before voxel-level decoding. Third, we introduce SEER-Loop, a dynamic skill-evolving strategy that distills high-reward reasoning trajectories into reusable skill artifacts and progressively integrates them into subsequent inference, enabling structured self-refinement and improved robustness to diverse linguistic expressions. Extensive experiments demonstrate superior performance of SEER over state-of-the-art baselines. Under linguistic perturbations, SEER reduces performance variance by 81.94% and improves worst-case Dice by 18.60%.

Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation

Vision-grounded medical report generation aims to produce clinically accurate descriptions of medical images, anchored in explicit visual evidence to improve interpretability and facilitate integration into clinical workflows. However, existing methods often rely on separately trained detection modules that require extensive expert annotations, introducing high labeling costs and limiting generalizability due to pathology distribution bias across datasets. To address these challenges, we propose Self-Supervised Anatomical Consistency Learning (SS-ACL) -- a novel and annotation-free framework that aligns generated reports with corresponding anatomical regions using simple textual prompts. SS-ACL constructs a hierarchical anatomical graph inspired by the invariant top-down inclusion structure of human anatomy, organizing entities by spatial location. It recursively reconstructs fine-grained anatomical regions to enforce intra-sample spatial alignment, inherently guiding attention maps toward visually relevant areas prompted by text. To further enhance inter-sample semantic alignment for abnormality recognition, SS-ACL introduces a region-level contrastive learning based on anatomical consistency. These aligned embeddings serve as priors for report generation, enabling attention maps to provide interpretable visual evidence. Extensive experiments demonstrate that SS-ACL, without relying on expert annotations, (i) generates accurate and visually grounded reports -- outperforming state-of-the-art methods by 10\% in lexical accuracy and 25\% in clinical efficacy, and (ii) achieves competitive performance on various downstream visual tasks, surpassing current leading visual foundation models by 8\% in zero-shot visual grounding.

  • 6 authors
·
Sep 30, 2025

Retrieval-Augmented Anatomical Guidance for Text-to-CT Generation

Text-conditioned generative models for volumetric medical imaging provide semantic control but lack explicit anatomical guidance, often resulting in outputs that are spatially ambiguous or anatomically inconsistent. In contrast, structure-driven methods ensure strong anatomical consistency but typically assume access to ground-truth annotations, which are unavailable when the target image is to be synthesized. We propose a retrieval-augmented approach for Text-to-CT generation that integrates semantic and anatomical information under a realistic inference setting. Given a radiology report, our method retrieves a semantically related clinical case using a 3D vision-language encoder and leverages its associated anatomical annotation as a structural proxy. This proxy is injected into a text-conditioned latent diffusion model via a ControlNet branch, providing coarse anatomical guidance while maintaining semantic flexibility. Experiments on the CT-RATE dataset show that retrieval-augmented generation improves image fidelity and clinical consistency compared to text-only baselines, while additionally enabling explicit spatial controllability, a capability inherently absent in such approaches. Further analysis highlights the importance of retrieval quality, with semantically aligned proxies yielding consistent gains across all evaluation axes. This work introduces a principled and scalable mechanism to bridge semantic conditioning and anatomical plausibility in volumetric medical image synthesis. Code will be released.

  • 4 authors
·
Mar 8

Test-time Adaptation of Pelvic Bone Segmentation Models via Dynamic Reliability-Guided

Reliable pelvic bone segmentation (PBS) from CT is essential for robot-assisted pelvic trauma surgery, yet deploying a source-trained model to a new hospital suffers from severe performance degradation due to cross-center domain shifts. While test-time adaptation (TTA) enables online model adaptation without accessing source data, existing methods show limited effectiveness for PBS, facing challenges including boundary degradation, anatomical inconsistency under domain shifts, and voxel-level class imbalance. To address these challenges, we propose a novel closed-loop dynamic Reliability-Guided TTA framework (ReGA) for PBS. Specifically, we introduce a pseudo-label reliability criterion termed Segmentation Inference Consistency Evaluation (SICE), which jointly measures region overlap and boundary deviation via dropout-based ensemble predictions. Based on SICE, a trust-weighted refinement module adaptively updates features to mitigate boundary errors in pseudo-labels. Furthermore, a confidence-weighted region-level contrastive learning strategy is proposed to enforce anatomical consistency. Finally, ReGA follows the teacher-student (TS) scheme to alleviate voxel-level class imbalance. Experiments on three heterogeneous 3D pelvic CT datasets demonstrate that ReGA consistently outperforms state-of-the-art TTA methods, enabling effective adaptation of the source-trained PBS model to unseen clinical domains. The code is available at https://github.com/Ren-ling/ReGA.

  • 5 authors
·
Jul 31

MosaicMRI: A Diverse Dataset and Benchmark for Raw Musculoskeletal MRI

Deep learning underpins a wide range of applications in MRI, including reconstruction, artifact removal, and segmentation. However, progress has been driven largely by public datasets focused on brain and knee imaging, shaping how models are trained and evaluated. As a result, careful studies of the reliability of these models across diverse anatomical settings remain limited. In this work, we introduce MosaicMRI, a large and diverse collection of fully sampled raw musculoskeletal (MSK) MR measurements designed for training and evaluating machine-learning-based methods. MosaicMRI is the largest open-source raw MSK MRI dataset to date, comprising 2,671 volumes and 80,156 slices. The dataset offers substantial diversity in volume orientation (e.g., axial, sagittal), imaging contrasts (e.g., PD, T1, T2), anatomies (e.g., spine, knee, hip, ankle, and others), and numbers of acquisition coils. Using VarNet as a baseline for accelerated reconstruction task, we perform a comprehensive set of experiments to study scaling behavior with respect to both model capacity and dataset size. Interestingly, models trained on the combined anatomies significantly outperform anatomy-specific models in low-sample regimes, highlighting the benefits of anatomical diversity and the presence of exploitable cross-anatomical correlations. We further evaluate robustness and cross-anatomy generalization by training models on one anatomy (e.g., spine) and testing them on another (e.g., knee). Notably, we identify groups of body parts (e.g., foot and elbow) that generalize well with each other, and highlight that performance under domain shifts depends on both training set size, anatomy, and protocol-specific factors.

  • 5 authors
·
Apr 12

BFSM: 3D Bidirectional Face-Skull Morphable Model

Building a joint face-skull morphable model holds great potential for applications such as remote diagnostics, surgical planning, medical education, and physically based facial simulation. However, realizing this vision is constrained by the scarcity of paired face-skull data, insufficient registration accuracy, and limited exploration of reconstruction and clinical applications. Moreover, individuals with craniofacial deformities are often overlooked, resulting in underrepresentation and limited inclusivity. To address these challenges, we first construct a dataset comprising over 200 samples, including both normal cases and rare craniofacial conditions. Each case contains a CT-based skull, a CT-based face, and a high-fidelity textured face scan. Secondly, we propose a novel dense ray matching registration method that ensures topological consistency across face, skull, and their tissue correspondences. Based on this, we introduce the 3D Bidirectional Face-Skull Morphable Model (BFSM), which enables shape inference between the face and skull through a shared coefficient space, while also modeling tissue thickness variation to support one-to-many facial reconstructions from the same skull, reflecting individual changes such as fat over time. Finally, we demonstrate the potential of BFSM in medical applications, including 3D face-skull reconstruction from a single image and surgical planning prediction. Extensive experiments confirm the robustness and accuracy of our method. BFSM is available at https://github.com/wang-zidu/BFSM

  • 8 authors
·
Sep 28, 2025

Assessment of Data Consistency through Cascades of Independently Recurrent Inference Machines for fast and robust accelerated MRI reconstruction

Machine Learning methods can learn how to reconstruct Magnetic Resonance Images and thereby accelerate acquisition, which is of paramount importance to the clinical workflow. Physics-informed networks incorporate the forward model of accelerated MRI reconstruction in the learning process. With increasing network complexity, robustness is not ensured when reconstructing data unseen during training. We aim to embed data consistency (DC) in deep networks while balancing the degree of network complexity. While doing so, we will assess whether either explicit or implicit enforcement of DC in varying network architectures is preferred to optimize performance. We propose a scheme called Cascades of Independently Recurrent Inference Machines (CIRIM) to assess DC through unrolled optimization. Herein we assess DC both implicitly by gradient descent and explicitly by a designed term. Extensive comparison of the CIRIM to CS as well as to other methods is performed: the E2EVN, CascadeNet, KIKINet, LPDNet, RIM, IRIM, and UNet. Models were trained and evaluated on T1-weighted and FLAIR contrast brain data, and T2-weighted knee data. Both 1D and 2D undersampling patterns were evaluated. Robustness was tested by reconstructing 7.5x prospectively undersampled 3D FLAIR MRI data of Multiple Sclerosis (MS) patients with white matter lesions. The CIRIM performed best when implicitly enforcing DC, while the E2EVN required an explicit DC formulation. In reconstructing MS patient data, prospectively acquired with a sampling pattern unseen during model training, the CIRIM maintained lesion contrast while efficiently denoising the images. The CIRIM showed highly promising generalization capabilities maintaining a very fair trade-off between reconstructed image quality and fast reconstruction times, which is crucial in the clinical workflow.

  • 5 authors
·
Nov 30, 2021

A Quantitative Evaluation of Dense 3D Reconstruction of Sinus Anatomy from Monocular Endoscopic Video

Generating accurate 3D reconstructions from endoscopic video is a promising avenue for longitudinal radiation-free analysis of sinus anatomy and surgical outcomes. Several methods for monocular reconstruction have been proposed, yielding visually pleasant 3D anatomical structures by retrieving relative camera poses with structure-from-motion-type algorithms and fusion of monocular depth estimates. However, due to the complex properties of the underlying algorithms and endoscopic scenes, the reconstruction pipeline may perform poorly or fail unexpectedly. Further, acquiring medical data conveys additional challenges, presenting difficulties in quantitatively benchmarking these models, understanding failure cases, and identifying critical components that contribute to their precision. In this work, we perform a quantitative analysis of a self-supervised approach for sinus reconstruction using endoscopic sequences paired with optical tracking and high-resolution computed tomography acquired from nine ex-vivo specimens. Our results show that the generated reconstructions are in high agreement with the anatomy, yielding an average point-to-mesh error of 0.91 mm between reconstructions and CT segmentations. However, in a point-to-point matching scenario, relevant for endoscope tracking and navigation, we found average target registration errors of 6.58 mm. We identified that pose and depth estimation inaccuracies contribute equally to this error and that locally consistent sequences with shorter trajectories generate more accurate reconstructions. These results suggest that achieving global consistency between relative camera poses and estimated depths with the anatomy is essential. In doing so, we can ensure proper synergy between all components of the pipeline for improved reconstructions that will facilitate clinical application of this innovative technology.

  • 12 authors
·
Oct 22, 2023

Dual-Prior Guided Null-Space Learning with Mixture-of-Splines for Arbitrary Medical Slice Super-Resolution

Arbitrary slice super-resolution reconstructs isotropic volumes from anisotropic clinical acquisitions by synthesizing intermediate slices at arbitrary scales. However, treating this ill-posed inverse problem as unconstrained residual-based regression risks hallucinating anatomically implausible structures or altering the originally observed data. To address both concerns, this paper presents the Dual-Prior Null-space Learning (DP-NSL) framework, which reformulates the task as a constrained recovery process guided by two complementary priors. A Measurement-Consistent Projection (MCP) enforces a Deterministic Observation Prior: the reconstruction undergoes an exact orthogonal projection that reproduces every acquired slice with zero error, confining all learned details to the unobservable null space. Within this null space, a Mixture-of-Splines (MoS) module imposes a Geometric Continuity Prior by dynamically mixing B-spline experts of different analytic orders, allowing each anatomical region to be modeled with a content-aware level of continuity. To promote spatial coherence, a Local Spatial Consistency Decoder (LSCD) further injects local inductive bias. Experiments on three CT and one MRI benchmark show that DP-NSL outperforms existing approaches while strictly preserving measurement consistency. Code is available at https://github.com/DeepMed-Lab-ECNU/Medical-Image-Reconstruction.

  • 6 authors
·
Jun 25

RadGenome-Anatomy: A Large-Scale Anatomy-Labeled Chest Radiograph Dataset via Physically Grounded Volumetric Projection

Anatomical structure labels for chest radiographs are essential for medical image segmentation and a broad range of downstream diagnostic tasks. However, annotating anatomy directly on 2D chest radiographs is labor-intensive and intrinsically ambiguous, as 3D anatomical structures are projected onto a single 2D plane where boundaries may overlap, be occluded, or appear only partially visible. Consequently, existing anatomy-labeled chest radiograph datasets remain limited in scale, anatomy coverage, and label reliability. To address these limitations, we introduce RadGenome-Anatomy, the largest anatomy-labeled chest radiograph dataset, containing over 10 million segmentation masks across 210 anatomical structures in 25,692 studies. It is constructed by projecting large-scale 3D anatomical masks from CT volumes into 2D radiographic space through canonical radiographic geometry. This shifts annotation from directly tracing uncertain 2D boundaries to defining anatomy in volumetric space, where structures that overlap or become partially invisible in radiographs remain spatially separable. As a result, each 2D mask represents the physically grounded projected footprint of a volumetrically defined structure. The scale and broad anatomical coverage of RadGenome-Anatomy, including structures that are overlapping, partially visible, or difficult to delineate directly, enable research on geometric measurements as explicit evidence for chest radiograph interpretation. We demonstrate this by training XAnatomy to predict structure-specific masks and derive clinically relevant measurements, achieving diagnostic accuracies of 96.4%, 95.6%, and 89.2% for cardiomegaly, kyphosis, and scoliosis, respectively.

  • 5 authors
·
May 16

SliceBridge: context-consistent repair of corrupted slice intervals in T1-weighted MRI

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.

Vision Tomography: Towards Portable 3D Bidirectional Face-Skull Inference from Visual Data

Traditional computed tomography (CT) can capture paired 3D face and skull geometry, but it remains costly, fixed in location, and exposes patients to radiation. For applications such as remote diagnostics, digital healthcare, forensic identification, missing-person investigation, and archaeological analysis, there is an urgent need for a portable, safe, and accessible solution to capture 3D skull geometry. In this work, we introduce Vision Tomography (VT), a concept and framework capable of reconstructing paired 3D face-skull geometry from various visual modalities, and also enabling joint manipulation of 3D facial and skull geometry. To achieve this, we first construct a dataset of over 200 samples, where each case includes a CT-based skull, a CT-based face, and a high-fidelity textured face scan. Secondly, we propose a novel dense ray matching registration method that ensures topological consistency across face, skull, and their tissue correspondences. Building on this registration, we introduce the 3D Bidirectional Face-Skull Morphable Model (BFSM) as the foundation of Vision Tomography, which enables shape inference between the face and skull through a shared coefficient space, while also modeling tissue thickness variation to support one-to-many facial reconstructions from the same skull, reflecting individual facial changes such as age or body fat. Finally, we demonstrate the effectiveness of Vision Tomography across various forensic and medical applications, including paired 3D face-skull reconstruction from images or sketches and predicting surgical outcomes with joint face-skull editing. Extensive experiments confirm the robustness and accuracy of our method. Vision Tomography is available at https://github.com/wang-zidu/BFSM

  • 8 authors
·
Oct 26

Anatomical Invariance Modeling and Semantic Alignment for Self-supervised Learning in 3D Medical Image Analysis

Self-supervised learning (SSL) has recently achieved promising performance for 3D medical image analysis tasks. Most current methods follow existing SSL paradigm originally designed for photographic or natural images, which cannot explicitly and thoroughly exploit the intrinsic similar anatomical structures across varying medical images. This may in fact degrade the quality of learned deep representations by maximizing the similarity among features containing spatial misalignment information and different anatomical semantics. In this work, we propose a new self-supervised learning framework, namely Alice, that explicitly fulfills Anatomical invariance modeling and semantic alignment via elaborately combining discriminative and generative objectives. Alice introduces a new contrastive learning strategy which encourages the similarity between views that are diversely mined but with consistent high-level semantics, in order to learn invariant anatomical features. Moreover, we design a conditional anatomical feature alignment module to complement corrupted embeddings with globally matched semantics and inter-patch topology information, conditioned by the distribution of local image content, which permits to create better contrastive pairs. Our extensive quantitative experiments on three 3D medical image analysis tasks demonstrate and validate the performance superiority of Alice, surpassing the previous best SSL counterpart methods and showing promising ability for united representation learning. Codes are available at https://github.com/alibaba-damo-academy/alice.

  • 7 authors
·
Feb 11, 2023

Landmark-free Assessment of Lower-limb Alignment with Implicit Neural Shape Functions from Knee Radiographs

Radiographic assessment of lower-limb alignment (LLA) is important for predicting joint health and surgical outcomes in total knee arthroplasty. Traditional measurement methods are manual and time-consuming, while recent machine learning approaches typically rely on locating a fixed set of anatomical landmarks. This dependence limits flexibility and may require re-annotation when clinical definitions change. To address this, we propose an automated workflow using Implicit Neural Shape Functions (INSF). Rather than relying on explicit landmark coordinates, we encode the anatomy into a compact latent space and regress clinical alignment measurements directly from these latent codes. This architecture allows for rapid extendability to new tasks without altering the backbone representation. We trained our method on an internal dataset of 566 knee radiographs, each annotated with the outline of the femur and tibia. We evaluated it on both an internal test dataset of 50 patients and a separate external set of 402 preoperative cases from the MRKR dataset. Manual clinical measurements are available for these data, and the MRKR measurements will be made publicly accessible. Performance was comparable to state-of-the-art landmark-based methods and manual agreement, while offering a flexible shape representation that can be extended to additional measurement tasks.

  • 8 authors
·
Jun 12

CADS: A Comprehensive Anatomical Dataset and Segmentation for Whole-Body Anatomy in Computed Tomography

Accurate delineation of anatomical structures in volumetric CT scans is crucial for diagnosis and treatment planning. While AI has advanced automated segmentation, current approaches typically target individual structures, creating a fragmented landscape of incompatible models with varying performance and disparate evaluation protocols. Foundational segmentation models address these limitations by providing a holistic anatomical view through a single model. Yet, robust clinical deployment demands comprehensive training data, which is lacking in existing whole-body approaches, both in terms of data heterogeneity and, more importantly, anatomical coverage. In this work, rather than pursuing incremental optimizations in model architecture, we present CADS, an open-source framework that prioritizes the systematic integration, standardization, and labeling of heterogeneous data sources for whole-body CT segmentation. At its core is a large-scale dataset of 22,022 CT volumes with complete annotations for 167 anatomical structures, representing a significant advancement in both scale and coverage, with 18 times more scans than existing collections and 60% more distinct anatomical targets. Building on this diverse dataset, we develop the CADS-model using established architectures for accessible and automated full-body CT segmentation. Through comprehensive evaluation across 18 public datasets and an independent real-world hospital cohort, we demonstrate advantages over SoTA approaches. Notably, thorough testing of the model's performance in segmentation tasks from radiation oncology validates its direct utility for clinical interventions. By making our large-scale dataset, our segmentation models, and our clinical software tool publicly available, we aim to advance robust AI solutions in radiology and make comprehensive anatomical analysis accessible to clinicians and researchers alike.

  • 33 authors
·
Jul 29, 2025

Large-Scale 3D Medical Image Pre-training with Geometric Context Priors

The scarcity of annotations poses a significant challenge in medical image analysis. Large-scale pre-training has emerged as a promising label-efficient solution, owing to the utilization of large-scale data, large models, and advanced pre-training techniques. However, its development in medical images remains underexplored. The primary challenge lies in harnessing large-scale unlabeled data and learning high-level semantics without annotations. We observe that 3D medical images exhibit consistent geometric context, i.e., consistent geometric relations between different organs, which leads to a promising way for learning consistent representations. Motivated by this, we introduce a simple-yet-effective Volume Contrast (VoCo) framework to leverage geometric context priors for self-supervision. Given an input volume, we extract base crops from different regions to construct positive and negative pairs for contrastive learning. Then we predict the contextual position of a random crop by contrasting its similarity to the base crops. In this way, VoCo encodes the inherent geometric context into model representations, facilitating high-level semantic learning without annotations. Specifically, we (1) introduce the largest medical pre-training dataset PreCT-160K; (2) investigate scaling laws and propose guidelines for tailoring different model sizes to various medical tasks; (3) build a benchmark encompassing 48 medical tasks. Extensive experiments highlight the superiority of VoCo. Codes at https://github.com/Luffy03/Large-Scale-Medical.

  • 3 authors
·
Oct 13, 2024

ICON: Improving Inter-Report Consistency of Radiology Report Generation via Lesion-aware Mix-up Augmentation

Previous research on radiology report generation has made significant progress in terms of increasing the clinical accuracy of generated reports. In this paper, we emphasize another crucial quality that it should possess, i.e., inter-report consistency, which refers to the capability of generating consistent reports for semantically equivalent radiographs. This quality is even of greater significance than the overall report accuracy in terms of ensuring the system's credibility, as a system prone to providing conflicting results would severely erode users' trust. Regrettably, existing approaches struggle to maintain inter-report consistency, exhibiting biases towards common patterns and susceptibility to lesion variants. To address this issue, we propose ICON, which improves the inter-report consistency of radiology report generation. Aiming at enhancing the system's ability to capture the similarities in semantically equivalent lesions, our approach involves first extracting lesions from input images and examining their characteristics. Then, we introduce a lesion-aware mix-up augmentation technique to ensure that the representations of the semantically equivalent lesions align with the same attributes, by linearly interpolating them during the training phase. Extensive experiments on three publicly available chest X-ray datasets verify the effectiveness of our approach, both in terms of improving the consistency and accuracy of the generated reports.

  • 6 authors
·
Feb 20, 2024

FleXray: Universal Clinical X-ray Segmentation

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

  • 5 authors
·
Sep 21

ΔRepresentation: Geometry Supervised Representation Learning of Phenotypes via Counterfactual Reasoning for Medical VLMs

Medical vision-language models (VLMs) have shown increasing potential for radiological image interpretation. Medical VLMs encode radiological images into visual representations that capture both anatomical and phenotypic information for diagnosis. Existing approaches improve pathological phenotype representations through semantic-guided representation alignment. However, pathological phenotypes arise as lesion-specific visual changes superimposed on underlying normal anatomy. Such semantic alignment approaches fail to model the phenotype-specific increment relative to the corresponding normal anatomical representation. To address this gap, we propose ΔRepresentation, a visual phenotype representation learning framework based on counterfactual reasoning for medical VLMs. It comprises BaseAnatomy, a geometry-supervised representation learning module, and ΔPhenotype, a counterfactual incremental representation learning module. BaseAnatomy provides fine-grained geometric supervision through spatial relationships across and within anatomical structures. ΔPhenotype computes the representation increment between lesion representations and their corresponding normal anatomical representations, and supervises increments associated with the same phenotype to cluster in the representation space. Experiments on ReXGroundingCT and LIDC-IDRI demonstrate that ΔRepresentation effectively structures pathological phenotype representations and improves lesion grounding and phenotype characterization accuracy in medical VLMs. Code is available at https://anonymous.4open.science/r/deltarep-CF6D.

  • 9 authors
·
Oct 6

DART: Scaling a Shape Representation Across Anatomical Classes and Imaging Modalities

Current state-of-the-art segmentation models still produce anatomically implausible shapes, such as broken vessels and fragmented glands, on the structures that are hardest to segment. Learned shape representations capture what structures look like and can help correct these errors, but most cover a fixed set of anatomical classes. Extending this coverage across classes and imaging modalities is costly because it often requires new voxel-level annotations. We propose Diffusion for Anatomical Reshaping with Text (DART), which learns a shared shape representation from segmentation probabilities. It uses anatomical descriptions to correct these probabilities without receiving medical images. Across 13 public benchmarks, absolute Dice gains reach 31% for individual gallbladder cases in CT and 10% for individual prostate cases in MRI. Using existing segmentation predictions, we scale a single shape representation from 50 to 377 anatomical classes without new voxel-level annotations for correction training. The shared representation also corrects four lesion classes absent from training and transfers from CT to MRI without retraining. Corrected labels also improve segmentation models, raising one model's Dice from 57.1% to 67.5%. The same pipeline supports annotations for 45,000 CT scans. These results suggest that sharing shape information within and across classes can reduce the need for new voxel-level annotations when extending segmentation to more anatomical classes and imaging modalities. The model is available at https://huggingface.co/Koushik45/DART-Seg

  • 7 authors
·
Oct 19

Segment as You Wish -- Free-Form Language-Based Segmentation for Medical Images

Medical imaging is crucial for diagnosing a patient's health condition, and accurate segmentation of these images is essential for isolating regions of interest to ensure precise diagnosis and treatment planning. Existing methods primarily rely on bounding boxes or point-based prompts, while few have explored text-related prompts, despite clinicians often describing their observations and instructions in natural language. To address this gap, we first propose a RAG-based free-form text prompt generator, that leverages the domain corpus to generate diverse and realistic descriptions. Then, we introduce FLanS, a novel medical image segmentation model that handles various free-form text prompts, including professional anatomy-informed queries, anatomy-agnostic position-driven queries, and anatomy-agnostic size-driven queries. Additionally, our model also incorporates a symmetry-aware canonicalization module to ensure consistent, accurate segmentations across varying scan orientations and reduce confusion between the anatomical position of an organ and its appearance in the scan. FLanS is trained on a large-scale dataset of over 100k medical images from 7 public datasets. Comprehensive experiments demonstrate the model's superior language understanding and segmentation precision, along with a deep comprehension of the relationship between them, outperforming SOTA baselines on both in-domain and out-of-domain datasets.

  • 7 authors
·
Oct 2, 2024

Synthetic Deformable Tubular Benchmark: A mechanically annotated dataset for evaluating deformable 3D reconstruction

Evaluating deformable 3D reconstruction requires ground truth linking camera motion, surface deformation, material correspondence and image appearance. We introduce the Synthetic Deformable Tubular Benchmark, generated with LumenMorph, an open-source toolkit for creating, annotating and evaluating tubular scenes. The release contains 5,580 RGB images. Its baseline crosses three surface-motion conditions with moving and stationary cameras in six scene families; matched appearance variants cover only moving-camera finite-element actions in four families. Documented public and evaluation interfaces expose camera poses, geometry, depth, deformation fields, persistent material correspondences and discrete finite-element records. Persistent triangle identities and material weights let users track the same surface location across frames and query its three-dimensional trajectory. Separately implemented geometric and mechanical checks assess annotation consistency with the generating models. Structure-from-motion, optical-flow and supplied-geometry displacement-interpolation studies demonstrate how the resource distinguishes registration coverage from geometric accuracy, exposes camera- and surface-motion effects, and tests the benefits and mismatch of mechanical priors. Public readers, evaluation contracts and the configurable generator support reuse and extension. Data integrity, fixed-environment repeatability and retained-prediction score replay have distinct verification scopes. The benchmark provides a controlled synthetic reference without claiming anatomical or clinical realism.

  • 1 authors
·
Oct 25

Detailed Annotations of Chest X-Rays via CT Projection for Report Understanding

In clinical radiology reports, doctors capture important information about the patient's health status. They convey their observations from raw medical imaging data about the inner structures of a patient. As such, formulating reports requires medical experts to possess wide-ranging knowledge about anatomical regions with their normal, healthy appearance as well as the ability to recognize abnormalities. This explicit grasp on both the patient's anatomy and their appearance is missing in current medical image-processing systems as annotations are especially difficult to gather. This renders the models to be narrow experts e.g. for identifying specific diseases. In this work, we recover this missing link by adding human anatomy into the mix and enable the association of content in medical reports to their occurrence in associated imagery (medical phrase grounding). To exploit anatomical structures in this scenario, we present a sophisticated automatic pipeline to gather and integrate human bodily structures from computed tomography datasets, which we incorporate in our PAXRay: A Projected dataset for the segmentation of Anatomical structures in X-Ray data. Our evaluation shows that methods that take advantage of anatomical information benefit heavily in visually grounding radiologists' findings, as our anatomical segmentations allow for up to absolute 50% better grounding results on the OpenI dataset as compared to commonly used region proposals. The PAXRay dataset is available at https://constantinseibold.github.io/paxray/.

  • 10 authors
·
Oct 7, 2022

Tracing Like a Clinician: Anatomy-Guided Spatial Priors for Cephalometric Landmark Detection

Clinicians trace cephalometric radiographs following a structured anatomical workflow, yet no prior system encodes this into computation. We present a five-phase anatomy-guided pipeline producing confidence-weighted spatial priors that shape HRNet-W32 training, achieving 1.04 mm mean radial error on 25 landmarks across 1,502 radiographs from 7+ imaging devices. A training x inference prior matrix isolates the mechanism: anatomical priors maintain a 1% validation-to-test gap versus 88% without priors (1.94 mm), despite identical validation convergence. The matrix establishes that all trained models are inference-independent, the expanded architecture alone provides no benefit, random priors yield partial but unstable improvement (1.72 mm), and only image-specific anatomically correct priors produce the 1.04 mm result -- functioning as a training-time regularizer requiring no automated prior generation at deployment. Five-fold cross-validation (p=0.0015), patient-level permutation testing (p<0.0001, n=151), quantified Grad-CAM analysis (88% vs. 74% in-zone activation, p<0.001), and clinical measurement validation (skeletal classification kappa=0.79-0.84, zero Class II<->III reversals, ICC>0.95) provide converging evidence. Cross-domain experiments on echocardiography, cervical spine, and hand radiography support the hypothesis that prior effectiveness scales with the spatial entropy of the landmark distribution.

  • 2 authors
·
Jun 1

AirMorph: Topology-Preserving Deep Learning for Pulmonary Airway Analysis

Accurate anatomical labeling and analysis of the pulmonary structure and its surrounding anatomy from thoracic CT is getting increasingly important for understanding the etilogy of abnormalities or supporting targetted therapy and early interventions. Whilst lung and airway cell atlases have been attempted, there is a lack of fine-grained morphological atlases that are clinically deployable. In this work, we introduce AirMorph, a robust, end-to-end deep learning pipeline enabling fully automatic and comprehensive airway anatomical labeling at lobar, segmental, and subsegmental resolutions that can be used to create digital atlases of the lung. Evaluated across large-scale multi-center datasets comprising diverse pulmonary conditions, the AirMorph consistently outperformed existing segmentation and labeling methods in terms of accuracy, topological consistency, and completeness. To simplify clinical interpretation, we further introduce a compact anatomical signature quantifying critical morphological airway features, including stenosis, ectasia, tortuosity, divergence, length, and complexity. When applied to various pulmonary diseases such as pulmonary fibrosis, emphysema, atelectasis, consolidation, and reticular opacities, it demonstrates strong discriminative power, revealing disease-specific morphological patterns with high interpretability and explainability. Additionally, AirMorph supports efficient automated branching pattern analysis, potentially enhancing bronchoscopic navigation planning and procedural safety, offering a valuable clinical tool for improved diagnosis, targeted treatment, and personalized patient care.

  • 11 authors
·
Dec 14, 2024

TotalSegmentator: robust segmentation of 104 anatomical structures in CT images

We present a deep learning segmentation model that can automatically and robustly segment all major anatomical structures in body CT images. In this retrospective study, 1204 CT examinations (from the years 2012, 2016, and 2020) were used to segment 104 anatomical structures (27 organs, 59 bones, 10 muscles, 8 vessels) relevant for use cases such as organ volumetry, disease characterization, and surgical or radiotherapy planning. The CT images were randomly sampled from routine clinical studies and thus represent a real-world dataset (different ages, pathologies, scanners, body parts, sequences, and sites). The authors trained an nnU-Net segmentation algorithm on this dataset and calculated Dice similarity coefficients (Dice) to evaluate the model's performance. The trained algorithm was applied to a second dataset of 4004 whole-body CT examinations to investigate age dependent volume and attenuation changes. The proposed model showed a high Dice score (0.943) on the test set, which included a wide range of clinical data with major pathologies. The model significantly outperformed another publicly available segmentation model on a separate dataset (Dice score, 0.932 versus 0.871, respectively). The aging study demonstrated significant correlations between age and volume and mean attenuation for a variety of organ groups (e.g., age and aortic volume; age and mean attenuation of the autochthonous dorsal musculature). The developed model enables robust and accurate segmentation of 104 anatomical structures. The annotated dataset (https://doi.org/10.5281/zenodo.6802613) and toolkit (https://www.github.com/wasserth/TotalSegmentator) are publicly available.

  • 12 authors
·
Aug 11, 2022

RibAssist 3D: Biplanar Rib-Fracture Detection, Addressing, and Selective 3D Localization from CT-Derived Projections

Rib fractures are common and time-consuming to localize on computed tomography (CT). We ask whether fractures detected independently in two orthogonal CT-derived projections (anteroposterior and lateral) can be paired across views and triangulated into reliable 3D points at a controlled rate of false outputs, and we answer it with a staged diagnostic study. The projection geometry is exact, and given correct correspondence, localization is accurate (median 4.0 mm, 88% within 10 mm, 93.6% rib-exact). On a sealed 55-case cohort, a large share of fractures is in principle recoverable (61.1% dual-view availability, and a correct pair present in the candidate graph for 58.4% of fractures), yet the binding limitation is neither geometry nor localization but confidence-limited cross-view correspondence. A controlled detector-by-correspondence factorial attributes the operational gain to lateral-detector quality rather than the tested matching methods; retraining the lateral detector produces the first nonzero controlled-budget reconstructions. Under a deliberately conservative commitment policy, a pre-specified sealed pass promotes 15 of 601 fractures to correct 3D localizations at 0.436 false points per case (2.50% end-to-end commitment yield), and committed points are accurate (median 1.49 mm, 93% rib-exact). The low yield is a consequence of confidence-gated abstention, not of geometry or detection: the study establishes a reproducible framework for selective 3D localization and identifies cross-view correspondence as the dominant operational bottleneck.

  • 1 authors
·
Aug 9 2

A skeletonization algorithm for gradient-based optimization

The skeleton of a digital image is a compact representation of its topology, geometry, and scale. It has utility in many computer vision applications, such as image description, segmentation, and registration. However, skeletonization has only seen limited use in contemporary deep learning solutions. Most existing skeletonization algorithms are not differentiable, making it impossible to integrate them with gradient-based optimization. Compatible algorithms based on morphological operations and neural networks have been proposed, but their results often deviate from the geometry and topology of the true medial axis. This work introduces the first three-dimensional skeletonization algorithm that is both compatible with gradient-based optimization and preserves an object's topology. Our method is exclusively based on matrix additions and multiplications, convolutional operations, basic non-linear functions, and sampling from a uniform probability distribution, allowing it to be easily implemented in any major deep learning library. In benchmarking experiments, we prove the advantages of our skeletonization algorithm compared to non-differentiable, morphological, and neural-network-based baselines. Finally, we demonstrate the utility of our algorithm by integrating it with two medical image processing applications that use gradient-based optimization: deep-learning-based blood vessel segmentation, and multimodal registration of the mandible in computed tomography and magnetic resonance images.

  • 9 authors
·
Sep 5, 2023

Parameter-Efficient Adaptation of SAM 3 for Automated ITV Generation from 4DCT Images

Four-dimensional computed tomography (4DCT) captures the full respiratory cycle of thoracic anatomy, yet current Internal Target Volume contouring workflows process each phase in isolation, discarding temporal coherence and leaving contours vulnerable to phase-specific artifacts. We present a lightweight framework that applies parameter-efficient fine-tuning to the Segment Anything Model 3 (SAM 3) via low-rank adaptation (LoRA) to align its text-prompted segmentation with the medical domain using only seven annotated 3D CT volumes. Furthermore, the framework incorporates a hard negative mining strategy to improve boundary discrimination in low-contrast thoracic regions. At inference, phase-wise predictions are refined through phase-coherent temporal filtering and spatial connectivity analysis. Since respiratory motion is continuous and periodic, genuine anatomy appears in contiguous blocks of phases, whereas transient artifacts appear sporadically and are thus effectively suppressed. Experiments on pulmonary and cardiac structures yield median Dice scores of 0.968 and 0.910 with 95th-percentile Hausdorff distances of 0.998 mm and 2.931 mm, respectively. The proposed framework effectively eliminates the severe false-positive predictions inherent in the zero-shot inference of the unadapted SAM 3. With only seven annotated volumes, the framework retains over 95% of full-data accuracy, and the entire pipeline is trainable on a single consumer-grade GPU, demonstrating a scalable, data-efficient solution for adaptive radiotherapy.

  • 1 authors
·
Jun 13

C3VDReg: A Benchmark for Local-to-Local Colonoscopic Registration toward Anatomical Localization

Anatomy-aware colonoscopic navigation requires localizing partial endoscopic observations on a stable 3D reference to support coverage assessment, revisited-region awareness, and CT-guided navigation. However, rigid point cloud registration in the colon differs fundamentally from standard benchmarks: surfaces are locally homogeneous, haustral folds are repetitive, views are highly partial, and reconstructed depth is noisy. We present C3VDReg, a dataset and benchmark derived from the Colonoscopy 3D Video Dataset (C3VD). For each frame, C3VDReg generates source point clouds via depth reprojection and target point clouds by raycasting CT meshes from matched camera poses. The benchmark comprises 10,015 viewpoint-matched partial-to-partial point cloud pairs (including 2,088 held-out test pairs) and evaluates baseline models under a standardized protocol: 8,192 points per cloud, source-only perturbations, fixed pose conventions, and unified metrics. Crucially, C3VDReg enables a systematic investigation of failure modes. We find that high geometric overlap alone is insufficient for reliable pose recovery: despite 74.3-93.1% ground-truth overlap, registration recall remains low across all evaluated methods. Through overlap, pose error, and translation decomposition analyses, we identify translation ambiguity along repetitive tubular anatomy as the primary bottleneck. This challenges the common assumption that increasing overlap or correspondence quality guarantees accurate registration, highlighting the need for stronger anatomical and contextual constraints. Code, model checkpoints, and data are available at https://github.com/linzhe001/C3VDReg .

  • 6 authors
·
Aug 24

IMPACT: A Generic Semantic Loss for Multimodal Medical Image Registration

Image registration is fundamental in medical imaging, enabling precise alignment of anatomical structures for diagnosis, treatment planning, image-guided treatment or longitudinal monitoring. This work introduces IMPACT (Image Metric with Pretrained model-Agnostic Comparison for Transmodality registration), a generic semantic similarity metric designed for seamless integration into diverse image registration frameworks (such as Elastix and Voxelmorph). It compares deep learning-based features extracted from medical images without requiring task-specific training, ensuring broad applicability across various modalities. By leveraging the features of the large-scale pretrained TotalSegmentator models and the ability to integrate Segment Anything Model (SAM) and other large-scale segmentation networks, this approach offers significant advantages. It provides robust, scalable, and efficient solutions for multimodal image registration. The IMPACT loss was evaluated on five challenging registration tasks involving thoracic CT/CBCT, and pelvic MR/CT datasets. Quantitative metrics, such as Target Registration Error and Dice Similarity Coefficient, demonstrated significant improvements in anatomical alignment compared to baseline methods. Qualitative analyses further confirmed the increased robustness of the proposed metric in the face of noise, artifacts, and modality variations. IMPACT's versatility and efficiency make it a valuable tool for advancing registration performance in clinical and research applications, addressing critical challenges in multimodal medical imaging.

  • 8 authors
·
Mar 31, 2025

SynthMorph: learning contrast-invariant registration without acquired images

We introduce a strategy for learning image registration without acquired imaging data, producing powerful networks agnostic to contrast introduced by magnetic resonance imaging (MRI). While classical registration methods accurately estimate the spatial correspondence between images, they solve an optimization problem for every new image pair. Learning-based techniques are fast at test time but limited to registering images with contrasts and geometric content similar to those seen during training. We propose to remove this dependency on training data by leveraging a generative strategy for diverse synthetic label maps and images that exposes networks to a wide range of variability, forcing them to learn more invariant features. This approach results in powerful networks that accurately generalize to a broad array of MRI contrasts. We present extensive experiments with a focus on 3D neuroimaging, showing that this strategy enables robust and accurate registration of arbitrary MRI contrasts even if the target contrast is not seen by the networks during training. We demonstrate registration accuracy surpassing the state of the art both within and across contrasts, using a single model. Critically, training on arbitrary shapes synthesized from noise distributions results in competitive performance, removing the dependency on acquired data of any kind. Additionally, since anatomical label maps are often available for the anatomy of interest, we show that synthesizing images from these dramatically boosts performance, while still avoiding the need for real intensity images. Our code is available at https://w3id.org/synthmorph.

  • 6 authors
·
Mar 2, 2022

Anatomical Foundation Models for Brain MRIs

Deep Learning (DL) in neuroimaging has become increasingly relevant for detecting neurological conditions and neurodegenerative disorders. One of the most predominant biomarkers in neuroimaging is represented by brain age, which has been shown to be a good indicator for different conditions, such as Alzheimer's Disease. Using brain age for weakly supervised pre-training of DL models in transfer learning settings has also recently shown promising results, especially when dealing with data scarcity of different conditions. On the other hand, anatomical information of brain MRIs (e.g. cortical thickness) can provide important information for learning good representations that can be transferred to many downstream tasks. In this work, we propose AnatCL, an anatomical foundation model for brain MRIs that i.) leverages anatomical information in a weakly contrastive learning approach, and ii.) achieves state-of-the-art performances across many different downstream tasks. To validate our approach we consider 12 different downstream tasks for the diagnosis of different conditions such as Alzheimer's Disease, autism spectrum disorder, and schizophrenia. Furthermore, we also target the prediction of 10 different clinical assessment scores using structural MRI data. Our findings show that incorporating anatomical information during pre-training leads to more robust and generalizable representations. Pre-trained models can be found at: https://github.com/EIDOSLAB/AnatCL.

  • 4 authors
·
Aug 7, 2024

Surgical Anatomy Recognition with Context Learning using Foundation Representations

Accurate recognition of anatomical structures is essential for safe and effective minimally invasive surgery (MIS), yet it remains underexplored in surgical computer vision due to limited annotated data and methods tailored primarily to natural scenes. In this work, we present a combined dataset and model framework to advance anatomy-aware perception in MIS. First, we introduce ATLAS-120k, a large-scale clip-level semantic segmentation dataset comprising over 120,000 annotated frames from 100 surgical videos spanning 14 procedures and multiple modalities, including laparoscopic and robot-assisted surgery. The dataset captures substantial procedural variability and was created using a scalable annotation pipeline that integrates expert manual labeling, automated propagation, iterative refinement, and surgeon verification to ensure high-quality annotations. Second, we propose ATLAS (Anatomy Recognition with Context Learning using Foundation Representations), a video semantic segmentation model specifically designed for surgical anatomy recognition. Unlike conventional approaches that emphasize object tracking, ATLAS leverages foundation-model embeddings together with lightweight temporal reasoning to incorporate contextual cues such as procedure type, surgical phase, and short-term visual memory. This design enables temporally consistent and accurate predictions while maintaining real-time feasibility. Together, the dataset and model establish a practical foundation for robust surgical scene understanding and support the development of clinically applicable guidance systems for minimally invasive surgery. The models, dataset annotations and annotation platform are publicly available at: https://github.com/TimJaspers0801/ATLAS.

  • 12 authors
·
Jun 19

MICDIR: Multi-scale Inverse-consistent Deformable Image Registration using UNetMSS with Self-Constructing Graph Latent

Image registration is the process of bringing different images into a common coordinate system - a technique widely used in various applications of computer vision, such as remote sensing, image retrieval, and, most commonly, medical imaging. Deep learning based techniques have been applied successfully to tackle various complex medical image processing problems, including medical image registration. Over the years, several image registration techniques have been proposed using deep learning. Deformable image registration techniques such as Voxelmorph have been successful in capturing finer changes and providing smoother deformations. However, Voxelmorph, as well as ICNet and FIRE, do not explicitly encode global dependencies (i.e. the overall anatomical view of the supplied image) and, therefore, cannot track large deformations. In order to tackle the aforementioned problems, this paper extends the Voxelmorph approach in three different ways. To improve the performance in case of small as well as large deformations, supervision of the model at different resolutions has been integrated using a multi-scale UNet. To support the network to learn and encode the minute structural co-relations of the given image-pairs, a self-constructing graph network (SCGNet) has been used as the latent of the multi-scale UNet - which can improve the learning process of the model and help the model to generalise better. And finally, to make the deformations inverse-consistent, cycle consistency loss has been employed. On the task of registration of brain MRIs, the proposed method achieved significant improvements over ANTs and VoxelMorph, obtaining a Dice score of 0.8013 \pm 0.0243 for intramodal and 0.6211 \pm 0.0309 for intermodal, while VoxelMorph achieved 0.7747 \pm 0.0260 and 0.6071 \pm 0.0510, respectively

  • 8 authors
·
Mar 8, 2022

TCMClinicalReason-Bench: Can Language Models Reason from Pathogenesis to Prescription over Real-World Clinical Cases?

Large language models (LLMs) can generate clinical narratives that are insufficiently grounded in patient-specific evidence. In traditional Chinese medicine (TCM), errors can propagate from etiology and pathogenesis through syndrome diagnosis and treatment principles to prescription generation. We developed TCMClinicalReason-Bench using 2,000 multicenter electronic health record cases to distinguish case-grounded responses from fluent but unsupported diagnostic and therapeutic conclusions. Five general-purpose and two TCM-specific LLMs were evaluated in zero-shot settings. An evidence-constrained rubric assessed seven diagnostic and therapeutic components and three cross-block relations, allowing case-supported alternatives. Qwen3.7-Plus with TCM retrieval served as the automated judge, alongside parallel blinded ratings by five senior TCM clinicians on a 600-case subset. Structural completeness was nearly saturated (99.3-100.0%), but normalized content scores ranged from 40.7% to 54.1%. The five general-purpose models averaged 50.0%, versus 41.3% for the two smaller TCM-specific models. Cross-block logic consistency ranged from 60.8% to 66.8% and correlated moderately with content across cases (Pearson's r = 0.515-0.656). Deficits were greatest in prescription generation, prescription analysis, and symptom-guided modification. In judge stress testing on 100 independent cases, perturbation detection rates across the three relations were 57%, 56%, and 31%, with contradictions detected more reliably than omissions. Separating component quality from cross-block consistency localizes failures missed by endpoint and completeness metrics and identifies where clinician oversight remains necessary.

  • 7 authors
·
Oct 2

Representing Part-Whole Hierarchies in Foundation Models by Learning Localizability, Composability, and Decomposability from Anatomy via Self-Supervision

Humans effortlessly interpret images by parsing them into part-whole hierarchies; deep learning excels in learning multi-level feature spaces, but they often lack explicit coding of part-whole relations, a prominent property of medical imaging. To overcome this limitation, we introduce Adam-v2, a new self-supervised learning framework extending Adam [79] by explicitly incorporating part-whole hierarchies into its learning objectives through three key branches: (1) Localizability, acquiring discriminative representations to distinguish different anatomical patterns; (2) Composability, learning each anatomical structure in a parts-to-whole manner; and (3) Decomposability, comprehending each anatomical structure in a whole-to-parts manner. Experimental results across 10 tasks, compared to 11 baselines in zero-shot, few-shot transfer, and full fine-tuning settings, showcase Adam-v2's superior performance over large-scale medical models and existing SSL methods across diverse downstream tasks. The higher generality and robustness of Adam-v2's representations originate from its explicit construction of hierarchies for distinct anatomical structures from unlabeled medical images. Adam-v2 preserves a semantic balance of anatomical diversity and harmony in its embedding, yielding representations that are both generic and semantically meaningful, yet overlooked in existing SSL methods. All code and pretrained models are available at https://github.com/JLiangLab/Eden.

  • 3 authors
·
Apr 24, 2024

ATLAS: Decoupling Skeletal and Shape Parameters for Expressive Parametric Human Modeling

Parametric body models offer expressive 3D representation of humans across a wide range of poses, shapes, and facial expressions, typically derived by learning a basis over registered 3D meshes. However, existing human mesh modeling approaches struggle to capture detailed variations across diverse body poses and shapes, largely due to limited training data diversity and restrictive modeling assumptions. Moreover, the common paradigm first optimizes the external body surface using a linear basis, then regresses internal skeletal joints from surface vertices. This approach introduces problematic dependencies between internal skeleton and outer soft tissue, limiting direct control over body height and bone lengths. To address these issues, we present ATLAS, a high-fidelity body model learned from 600k high-resolution scans captured using 240 synchronized cameras. Unlike previous methods, we explicitly decouple the shape and skeleton bases by grounding our mesh representation in the human skeleton. This decoupling enables enhanced shape expressivity, fine-grained customization of body attributes, and keypoint fitting independent of external soft-tissue characteristics. ATLAS outperforms existing methods by fitting unseen subjects in diverse poses more accurately, and quantitative evaluations show that our non-linear pose correctives more effectively capture complex poses compared to linear models.

  • 10 authors
·
Aug 21, 2025 2

Diffusion-Based Quality Control of Medical Image Segmentations across Organs

Medical image segmentation using deep learning (DL) has enabled the development of automated analysis pipelines for large-scale population studies. However, state-of-the-art DL methods are prone to hallucinations, which can result in anatomically implausible segmentations. With manual correction impractical at scale, automated quality control (QC) techniques have to address the challenge. While promising, existing QC methods are organ-specific, limiting their generalizability and usability beyond their original intended task. To overcome this limitation, we propose no-new Quality Control (nnQC), a robust QC framework based on a diffusion-generative paradigm that self-adapts to any input organ dataset. Central to nnQC is a novel Team of Experts (ToE) architecture, where two specialized experts independently encode 3D spatial awareness, represented by the relative spatial position of an axial slice, and anatomical information derived from visual features from the original image. A weighted conditional module dynamically combines the pair of independent embeddings, or opinions to condition the sampling mechanism within a diffusion process, enabling the generation of a spatially aware pseudo-ground truth for predicting QC scores. Within its framework, nnQC integrates fingerprint adaptation to ensure adaptability across organs, datasets, and imaging modalities. We evaluated nnQC on seven organs using twelve publicly available datasets. Our results demonstrate that nnQC consistently outperforms state-of-the-art methods across all experiments, including cases where segmentation masks are highly degraded or completely missing, confirming its versatility and effectiveness across different organs.

  • 7 authors
·
Mar 29

Multi-view X-ray Image Synthesis with Multiple Domain Disentanglement from CT Scans

X-ray images play a vital role in the intraoperative processes due to their high resolution and fast imaging speed and greatly promote the subsequent segmentation, registration and reconstruction. However, over-dosed X-rays superimpose potential risks to human health to some extent. Data-driven algorithms from volume scans to X-ray images are restricted by the scarcity of paired X-ray and volume data. Existing methods are mainly realized by modelling the whole X-ray imaging procedure. In this study, we propose a learning-based approach termed CT2X-GAN to synthesize the X-ray images in an end-to-end manner using the content and style disentanglement from three different image domains. Our method decouples the anatomical structure information from CT scans and style information from unpaired real X-ray images/ digital reconstructed radiography (DRR) images via a series of decoupling encoders. Additionally, we introduce a novel consistency regularization term to improve the stylistic resemblance between synthesized X-ray images and real X-ray images. Meanwhile, we also impose a supervised process by computing the similarity of computed real DRR and synthesized DRR images. We further develop a pose attention module to fully strengthen the comprehensive information in the decoupled content code from CT scans, facilitating high-quality multi-view image synthesis in the lower 2D space. Extensive experiments were conducted on the publicly available CTSpine1K dataset and achieved 97.8350, 0.0842 and 3.0938 in terms of FID, KID and defined user-scored X-ray similarity, respectively. In comparison with 3D-aware methods (pi-GAN, EG3D), CT2X-GAN is superior in improving the synthesis quality and realistic to the real X-ray images.

  • 9 authors
·
Apr 18, 2024

SCORPION: Addressing Scanner-Induced Variability in Histopathology

Ensuring reliable model performance across diverse domains is a critical challenge in computational pathology. A particular source of variability in Whole-Slide Images is introduced by differences in digital scanners, thus calling for better scanner generalization. This is critical for the real-world adoption of computational pathology, where the scanning devices may differ per institution or hospital, and the model should not be dependent on scanner-induced details, which can ultimately affect the patient's diagnosis and treatment planning. However, past efforts have primarily focused on standard domain generalization settings, evaluating on unseen scanners during training, without directly evaluating consistency across scanners for the same tissue. To overcome this limitation, we introduce SCORPION, a new dataset explicitly designed to evaluate model reliability under scanner variability. SCORPION includes 480 tissue samples, each scanned with 5 scanners, yielding 2,400 spatially aligned patches. This scanner-paired design allows for the isolation of scanner-induced variability, enabling a rigorous evaluation of model consistency while controlling for differences in tissue composition. Furthermore, we propose SimCons, a flexible framework that combines augmentation-based domain generalization techniques with a consistency loss to explicitly address scanner generalization. We empirically show that SimCons improves model consistency on varying scanners without compromising task-specific performance. By releasing the SCORPION dataset and proposing SimCons, we provide the research community with a crucial resource for evaluating and improving model consistency across diverse scanners, setting a new standard for reliability testing.

  • 7 authors
·
Sep 17, 2025

OrthoDiffusion: A Generalizable Multi-Task Diffusion Foundation Model for Musculoskeletal MRI Interpretation

Musculoskeletal disorders represent a significant global health burden and are a leading cause of disability worldwide. While MRI is essential for accurate diagnosis, its interpretation remains exceptionally challenging. Radiologists must identify multiple potential abnormalities within complex anatomical structures across different imaging planes, a process that requires significant expertise and is prone to variability. We developed OrthoDiffusion, a unified diffusion-based foundation model designed for multi-task musculoskeletal MRI interpretation. The framework utilizes three orientation-specific 3D diffusion models, pre-trained in a self-supervised manner on 15,948 unlabeled knee MRI scans, to learn robust anatomical features from sagittal, coronal, and axial views. These view-specific representations are integrated to support diverse clinical tasks, including anatomical segmentation and multi-label diagnosis. Our evaluation demonstrates that OrthoDiffusion achieves excellent performance in the segmentation of 11 knee structures and the detection of 8 knee abnormalities. The model exhibited remarkable robustness across different clinical centers and MRI field strengths, consistently outperforming traditional supervised models. Notably, in settings where labeled data was scarce, OrthoDiffusion maintained high diagnostic precision using only 10\% of training labels. Furthermore, the anatomical representations learned from knee imaging proved highly transferable to other joints, achieving strong diagnostic performance across 11 diseases of the ankle and shoulder. These findings suggest that diffusion-based foundation models can serve as a unified platform for multi-disease diagnosis and anatomical segmentation, potentially improving the efficiency and accuracy of musculoskeletal MRI interpretation in real-world clinical workflows.

  • 11 authors
·
Feb 23

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8pm21.3 HU, PSNR sim30 dB, MS-SSIM sim0.936, Dice 0.79, photon γ_{2%/2mm}>98%, proton γapprox85%. Task 2 improved: MAE 48.3pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%, proton γapprox89%. Strong image--segmentation correlations (ρ=0.78--0.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.

  • 33 authors
·
May 12

MRSegmentator: Robust Multi-Modality Segmentation of 40 Classes in MRI and CT Sequences

Purpose: To introduce a deep learning model capable of multi-organ segmentation in MRI scans, offering a solution to the current limitations in MRI analysis due to challenges in resolution, standardized intensity values, and variability in sequences. Materials and Methods: he model was trained on 1,200 manually annotated MRI scans from the UK Biobank, 221 in-house MRI scans and 1228 CT scans, leveraging cross-modality transfer learning from CT segmentation models. A human-in-the-loop annotation workflow was employed to efficiently create high-quality segmentations. The model's performance was evaluated on NAKO and the AMOS22 dataset containing 600 and 60 MRI examinations. Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD) was used to assess segmentation accuracy. The model will be open sourced. Results: The model showcased high accuracy in segmenting well-defined organs, achieving Dice Similarity Coefficient (DSC) scores of 0.97 for the right and left lungs, and 0.95 for the heart. It also demonstrated robustness in organs like the liver (DSC: 0.96) and kidneys (DSC: 0.95 left, 0.95 right), which present more variability. However, segmentation of smaller and complex structures such as the portal and splenic veins (DSC: 0.54) and adrenal glands (DSC: 0.65 left, 0.61 right) revealed the need for further model optimization. Conclusion: The proposed model is a robust, tool for accurate segmentation of 40 anatomical structures in MRI and CT images. By leveraging cross-modality learning and interactive annotation, the model achieves strong performance and generalizability across diverse datasets, making it a valuable resource for researchers and clinicians. It is open source and can be downloaded from https://github.com/hhaentze/MRSegmentator.

  • 11 authors
·
May 10, 2024

Generating Synthetic Computed Tomography for Radiotherapy: SynthRAD2023 Challenge Report

Radiation therapy plays a crucial role in cancer treatment, necessitating precise delivery of radiation to tumors while sparing healthy tissues over multiple days. Computed tomography (CT) is integral for treatment planning, offering electron density data crucial for accurate dose calculations. However, accurately representing patient anatomy is challenging, especially in adaptive radiotherapy, where CT is not acquired daily. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast. Still, it lacks electron density information while cone beam CT (CBCT) lacks direct electron density calibration and is mainly used for patient positioning. Adopting MRI-only or CBCT-based adaptive radiotherapy eliminates the need for CT planning but presents challenges. Synthetic CT (sCT) generation techniques aim to address these challenges by using image synthesis to bridge the gap between MRI, CBCT, and CT. The SynthRAD2023 challenge was organized to compare synthetic CT generation methods using multi-center ground truth data from 1080 patients, divided into two tasks: 1) MRI-to-CT and 2) CBCT-to-CT. The evaluation included image similarity and dose-based metrics from proton and photon plans. The challenge attracted significant participation, with 617 registrations and 22/17 valid submissions for tasks 1/2. Top-performing teams achieved high structural similarity indices (>0.87/0.90) and gamma pass rates for photon (>98.1%/99.0%) and proton (>99.0%/97.3%) plans. However, no significant correlation was found between image similarity metrics and dose accuracy, emphasizing the need for dose evaluation when assessing the clinical applicability of sCT. SynthRAD2023 facilitated the investigation and benchmarking of sCT generation techniques, providing insights for developing MRI-only and CBCT-based adaptive radiotherapy.

  • 59 authors
·
Mar 13, 2024

Progression as Latent Drift: Generative Forecasting of Slow-Evolving Pathologies

Forecasting the future anatomy of slow-evolving neurodegenerative diseases could enable earlier, more targeted intervention and improve clinical trial design, but it remains challenging because true progression signals are subtle in longitudinal MRI. In this low-signal regime, transferring modern generative sequence models directly is unreliable: training is dominated by stable baseline anatomy and confounded by dense, sample-specific nuisance variation. We first provide a theoretical analysis that explains these failures through two modes. Identity collapse occurs when optimization is driven toward reproducing the current anatomy, which prevents the model from learning faint temporal change. The continuous interpolation trap arises when standard smooth networks cannot separate localized biological drift from pervasive noise, which leads to spurious changes that diffuse across the volume. To address both issues, we propose Latent Drift, a progressive generative framework that learns change in a compressed semantic representation rather than synthesizing full-resolution anatomy. This design removes pixel-level identity from the prediction target and concentrates model capacity on progression-relevant dynamics. We further apply Finite Scalar Quantization to the learned change representation, which suppresses small, high-frequency nuisance fluctuations while preserving consistent structural drift. Experiments on longitudinal 3D brain MRI show that Latent Drift improves patient-specific neuro-forecasting over diffusion and autoregressive transformer baselines across generative fidelity and clinically relevant evaluation metrics. Project page: https://cutepkq.github.io/latent-drift{https://cutepkq.github.io/latent-drift}.

  • 10 authors
·
Jul 8

AnyCXR: Human Anatomy Segmentation of Chest X-ray at Any Acquisition Position using Multi-stage Domain Randomized Synthetic Data with Imperfect Annotations and Conditional Joint Annotation Regularization Learning

Robust anatomical segmentation of chest X-rays (CXRs) remains challenging due to the scarcity of comprehensive annotations and the substantial variability of real-world acquisition conditions. We propose AnyCXR, a unified framework that enables generalizable multi-organ segmentation across arbitrary CXR projection angles using only synthetic supervision. The method combines a Multi-stage Domain Randomization (MSDR) engine, which generates over 100,000 anatomically faithful and highly diverse synthetic radiographs from 3D CT volumes, with a Conditional Joint Annotation Regularization (CAR) learning strategy that leverages partial and imperfect labels by enforcing anatomical consistency in a latent space. Trained entirely on synthetic data, AnyCXR achieves strong zero-shot generalization on multiple real-world datasets, providing accurate delineation of 54 anatomical structures in PA, lateral, and oblique views. The resulting segmentation maps support downstream clinical tasks, including automated cardiothoracic ratio estimation, spine curvature assessment, and disease classification, where the incorporation of anatomical priors improves diagnostic performance. These results demonstrate that AnyCXR establishes a scalable and reliable foundation for anatomy-aware CXR analysis and offers a practical pathway toward reducing annotation burdens while improving robustness across diverse imaging conditions.

  • 6 authors
·
Jan 1

Considerations for Using the Vasculature as a Coordinate System to Map All the Cells in the Human Body

Several ongoing international efforts are developing methods of localizing single cells within organs or mapping the entire human body at the single cell level, including the Chan Zuckerberg Initiative's Human Cell Atlas (HCA), and the Knut and Allice Wallenberg Foundation's Human Protein Atlas (HPA), and the National Institutes of Health's Human BioMolecular Atlas Program (HuBMAP). Their goals are to understand cell specialization, interactions, spatial organization in their natural context, and ultimately the function of every cell within the body. In the same way that the Human Genome Project had to assemble sequence data from different people to construct a complete sequence, multiple centers around the world are collecting tissue specimens from a diverse population that varies in age, race, sex, and body size. A challenge will be combining these heterogeneous tissue samples into a 3D reference map that will enable multiscale, multidimensional Google Maps-like exploration of the human body. Key to making alignment of tissue samples work is identifying and using a coordinate system called a Common Coordinate Framework (CCF), which defines the positions, or "addresses", in a reference body, from whole organs down to functional tissue units and individual cells. In this perspective, we examine the concept of a CCF based on the vasculature and describe why it would be an attractive choice for mapping the human body.

  • 3 authors
·
Nov 7, 2019

Calibration and Uncertainty for multiRater Volume Assessment in multiorgan Segmentation (CURVAS) challenge results

Deep learning (DL) has become the dominant approach for medical image segmentation, yet ensuring the reliability and clinical applicability of these models requires addressing key challenges such as annotation variability, calibration, and uncertainty estimation. This is why we created the Calibration and Uncertainty for multiRater Volume Assessment in multiorgan Segmentation (CURVAS), which highlights the critical role of multiple annotators in establishing a more comprehensive ground truth, emphasizing that segmentation is inherently subjective and that leveraging inter-annotator variability is essential for robust model evaluation. Seven teams participated in the challenge, submitting a variety of DL models evaluated using metrics such as Dice Similarity Coefficient (DSC), Expected Calibration Error (ECE), and Continuous Ranked Probability Score (CRPS). By incorporating consensus and dissensus ground truth, we assess how DL models handle uncertainty and whether their confidence estimates align with true segmentation performance. Our findings reinforce the importance of well-calibrated models, as better calibration is strongly correlated with the quality of the results. Furthermore, we demonstrate that segmentation models trained on diverse datasets and enriched with pre-trained knowledge exhibit greater robustness, particularly in cases deviating from standard anatomical structures. Notably, the best-performing models achieved high DSC and well-calibrated uncertainty estimates. This work underscores the need for multi-annotator ground truth, thorough calibration assessments, and uncertainty-aware evaluations to develop trustworthy and clinically reliable DL-based medical image segmentation models.

  • 32 authors
·
May 13, 2025

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

  • 1 authors
·
Oct 11

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

  • 9 authors
·
Oct 24

Robotic Ultrasound Makes CBCT Alive

Intraoperative Cone Beam Computed Tomography (CBCT) provides a reliable 3D anatomical context essential for interventional planning. However, its static nature fails to provide continuous monitoring of soft-tissue deformations induced by respiration, probe pressure, and surgical manipulation, leading to navigation discrepancies. We propose a deformation-aware CBCT updating framework that leverages robotic ultrasound as a dynamic proxy to infer tissue motion and update static CBCT slices in real time. Starting from calibration-initialized alignment with linear correlation of linear combination (LC2)-based rigid refinement, our method establishes accurate multimodal correspondence. To capture intraoperative dynamics, we introduce the ultrasound correlation UNet (USCorUNet), a lightweight network trained with optical flow-guided supervision to learn deformation-aware correlation representations, enabling accurate, real-time dense deformation field estimation from ultrasound streams. The inferred deformation is spatially regularized and transferred to the CBCT reference to produce deformation-consistent visualizations without repeated radiation exposure. We validate the proposed approach through deformation estimation and ultrasound-guided CBCT updating experiments. Results demonstrate real-time end-to-end CBCT slice updating and physically plausible deformation estimation, enabling dynamic refinement of static CBCT guidance during robotic ultrasound-assisted interventions. The source code is publicly available at https://github.com/anonymous-codebase/us-cbct-demo.

  • 5 authors
·
Mar 9

3DReasonKnee: Advancing Grounded Reasoning in Medical Vision Language Models

Current Vision-Language Models (VLMs) struggle to ground anatomical regions in 3D medical images and reason about them in a step-by-step manner, a key requirement of real-world diagnostic assessment. This ability is essential for aligning model outputs with the diagnostic workflows clinicians use in practice, enabling trustworthy clinician-AI collaboration. Existing 3D datasets provide localization labels, but none support this "grounded reasoning" ability. To address this gap, we introduce 3DReasonKnee, the first 3D grounded reasoning dataset for medical images, which provides 494k high-quality quintuples derived from 7,970 3D knee MRI volumes. Each quintuple includes: (1) the 3D MRI volume, (2) a diagnostic question targeting a specific anatomical region (3) a 3D bounding box localizing the relevant anatomical structures, (4) clinician-generated diagnostic reasoning steps that explicitly detail the 3D reasoning process, and (5) structured severity assessments for the relevant anatomical region. The creation and validation of 3DReasonKnee, involving over 450 hours of expert clinician time for manually segmenting MRIs and generating reasoning chains, ensures its superior quality and clinical relevance. We establish ReasonKnee-Bench to evaluate localization and diagnostic accuracy, providing insight into VLM ability to perform grounding and severity assessment across anatomical regions and diagnostic inquiries. We benchmark five state-of-the-art VLMs, providing baseline performance for ReasonKnee-Bench. By providing this unique resource of expert-annotated 3D reasoning pathways, 3DReasonKnee serves as a repository of orthopedic surgeons' diagnostic expertise and offers a vital testbed for advancing multimodal medical AI systems towards 3D, clinically aligned, localized decision-making capabilities. The dataset can be found in: https://huggingface.co/datasets/rajpurkarlab/3DReasonKnee

  • 8 authors
·
Oct 23, 2025

CheXWorld: Exploring Image World Modeling for Radiograph Representation Learning

Humans can develop internal world models that encode common sense knowledge, telling them how the world works and predicting the consequences of their actions. This concept has emerged as a promising direction for establishing general-purpose machine-learning models in recent preliminary works, e.g., for visual representation learning. In this paper, we present CheXWorld, the first effort towards a self-supervised world model for radiographic images. Specifically, our work develops a unified framework that simultaneously models three aspects of medical knowledge essential for qualified radiologists, including 1) local anatomical structures describing the fine-grained characteristics of local tissues (e.g., architectures, shapes, and textures); 2) global anatomical layouts describing the global organization of the human body (e.g., layouts of organs and skeletons); and 3) domain variations that encourage CheXWorld to model the transitions across different appearance domains of radiographs (e.g., varying clarity, contrast, and exposure caused by collecting radiographs from different hospitals, devices, or patients). Empirically, we design tailored qualitative and quantitative analyses, revealing that CheXWorld successfully captures these three dimensions of medical knowledge. Furthermore, transfer learning experiments across eight medical image classification and segmentation benchmarks showcase that CheXWorld significantly outperforms existing SSL methods and large-scale medical foundation models. Code & pre-trained models are available at https://github.com/LeapLabTHU/CheXWorld.

  • 6 authors
·
Apr 18, 2025 2

Accurate Fine-Grained Segmentation of Human Anatomy in Radiographs via Volumetric Pseudo-Labeling

Purpose: Interpreting chest radiographs (CXR) remains challenging due to the ambiguity of overlapping structures such as the lungs, heart, and bones. To address this issue, we propose a novel method for extracting fine-grained anatomical structures in CXR using pseudo-labeling of three-dimensional computed tomography (CT) scans. Methods: We created a large-scale dataset of 10,021 thoracic CTs with 157 labels and applied an ensemble of 3D anatomy segmentation models to extract anatomical pseudo-labels. These labels were projected onto a two-dimensional plane, similar to the CXR, allowing the training of detailed semantic segmentation models for CXR without any manual annotation effort. Results: Our resulting segmentation models demonstrated remarkable performance on CXR, with a high average model-annotator agreement between two radiologists with mIoU scores of 0.93 and 0.85 for frontal and lateral anatomy, while inter-annotator agreement remained at 0.95 and 0.83 mIoU. Our anatomical segmentations allowed for the accurate extraction of relevant explainable medical features such as the cardio-thoracic-ratio. Conclusion: Our method of volumetric pseudo-labeling paired with CT projection offers a promising approach for detailed anatomical segmentation of CXR with a high agreement with human annotators. This technique may have important clinical implications, particularly in the analysis of various thoracic pathologies.

  • 8 authors
·
Jun 5, 2023

SA-CycleGAN-2.5D: Self-Attention CycleGAN with Tri-Planar Context for Multi-Site MRI Harmonization

Multi-site neuroimaging analysis is fundamentally confounded by scanner-induced covariate shifts, where the marginal distribution of voxel intensities P(x) varies non-linearly across acquisition protocols while the conditional anatomy P(y|x) remains constant. This is particularly detrimental to radiomic reproducibility, where acquisition variance often exceeds biological pathology variance. Existing statistical harmonization methods (e.g., ComBat) operate in feature space, precluding spatial downstream tasks, while standard deep learning approaches are theoretically bounded by local effective receptive fields (ERF), failing to model the global intensity correlations characteristic of field-strength bias. We propose SA-CycleGAN-2.5D, a domain adaptation framework motivated by the HΔH-divergence bound of Ben-David et al., integrating three architectural innovations: (1) A 2.5D tri-planar manifold injection preserving through-plane gradients nabla_z at O(HW) complexity; (2) A U-ResNet generator with dense voxel-to-voxel self-attention, surpassing the O(L) receptive field limit of CNNs to model global scanner field biases; and (3) A spectrally-normalized discriminator constraining the Lipschitz constant (K_D le 1) for stable adversarial optimization. Evaluated on 654 glioma patients across two institutional domains (BraTS and UPenn-GBM), our method reduces Maximum Mean Discrepancy (MMD) by 99.1% (1.729 to 0.015) and degrades domain classifier accuracy to near-chance (59.7%). Ablation confirms that global attention is statistically essential (Cohen's d = 1.32, p < 0.001) for the harder heterogeneous-to-homogeneous translation direction. By bridging 2D efficiency and 3D consistency, our framework yields voxel-level harmonized images that preserve tumor pathophysiology, enabling reproducible multi-center radiomic analysis.

  • 2 authors
·
Mar 17

VoCo: A Simple-yet-Effective Volume Contrastive Learning Framework for 3D Medical Image Analysis

Self-Supervised Learning (SSL) has demonstrated promising results in 3D medical image analysis. However, the lack of high-level semantics in pre-training still heavily hinders the performance of downstream tasks. We observe that 3D medical images contain relatively consistent contextual position information, i.e., consistent geometric relations between different organs, which leads to a potential way for us to learn consistent semantic representations in pre-training. In this paper, we propose a simple-yet-effective Volume Contrast (VoCo) framework to leverage the contextual position priors for pre-training. Specifically, we first generate a group of base crops from different regions while enforcing feature discrepancy among them, where we employ them as class assignments of different regions. Then, we randomly crop sub-volumes and predict them belonging to which class (located at which region) by contrasting their similarity to different base crops, which can be seen as predicting contextual positions of different sub-volumes. Through this pretext task, VoCo implicitly encodes the contextual position priors into model representations without the guidance of annotations, enabling us to effectively improve the performance of downstream tasks that require high-level semantics. Extensive experimental results on six downstream tasks demonstrate the superior effectiveness of VoCo. Code will be available at https://github.com/Luffy03/VoCo.

  • 3 authors
·
Feb 27, 2024

SERV-CT: A disparity dataset from CT for validation of endoscopic 3D reconstruction

In computer vision, reference datasets have been highly successful in promoting algorithmic development in stereo reconstruction. Surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surfaces and the presence of blood and smoke. Publicly available datasets have been produced using CT and either phantom images or biological tissue samples covering a relatively small region of the endoscope field-of-view. We present a stereo-endoscopic reconstruction validation dataset based on CT (SERV-CT). Two {\it ex vivo} small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Orientation of the endoscope was manually aligned to the stereoscopic view. Reference disparities and occlusions were calculated for 8 stereo pairs from each sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of ~2 pixels and a depth accuracy of ~2mm. The reference dataset includes endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types. Smooth specular surfaces and images with significant variation of depth are included. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths with coverage over the majority of the endoscopic images. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms.

  • 5 authors
·
Dec 21, 2020

MeDSLIP: Medical Dual-Stream Language-Image Pre-training for Fine-grained Alignment

Vision-language pre-training (VLP) models have shown significant advancements in the medical domain. Yet, most VLP models align raw reports to images at a very coarse level, without modeling fine-grained relationships between anatomical and pathological concepts outlined in reports and the corresponding semantic counterparts in images. To address this problem, we propose a Medical Dual-Stream Language-Image Pre-training (MeDSLIP) framework. Specifically, MeDSLIP establishes vision-language fine-grained alignments via disentangling visual and textual representations into anatomy-relevant and pathology-relevant streams. Moreover, a novel vision-language Prototypical Contr-astive Learning (ProtoCL) method is adopted in MeDSLIP to enhance the alignment within the anatomical and pathological streams. MeDSLIP further employs cross-stream Intra-image Contrastive Learning (ICL) to ensure the consistent coexistence of paired anatomical and pathological concepts within the same image. Such a cross-stream regularization encourages the model to exploit the synchrony between two streams for a more comprehensive representation learning. MeDSLIP is evaluated under zero-shot and supervised fine-tuning settings on three public datasets: NIH CXR14, RSNA Pneumonia, and SIIM-ACR Pneumothorax. Under these settings, MeDSLIP outperforms six leading CNN-based models on classification, grounding, and segmentation tasks.

  • 9 authors
·
Mar 15, 2024

OrganLens: Organ-Specific Representation Learning for CT Foundation Models

A CT examination captures multiple organs, but many biomedical questions concern abnormalities, prognosis, or longitudinal change in a specific organ. These questions require a separate representation for each organ within the same CT volume. Existing CT foundation models commonly produce a single volume-level representation, while recent anatomy-aware methods either encode pre-separated organ volumes or explicitly disentangle images into organ token groups. The former may remove clinically relevant surrounding context, while the latter does not condition a shared encoder on a selected organ before its features are formed. We introduce OrganLens for organ-specific representation learning through self-supervision. An organ identity conditions a shared CT encoder, while organ-specific distillation and anatomy-mask supervision shape features for anatomy-weighted pooling into organ-specific representations. At inference, the shared model produces 11 organ-specific representations without external segmentation masks. We evaluate OrganLens on CT-RATE, RAD-ChestCT, INSPECT, and NLST across diverse acquisitions and downstream evaluations. Relative to CT-pretrained DINOv2, heart representations raise CT-RATE cardiomegaly AUROC from 0.910 to 0.953, while lung representations improve the Harrell C-index for NLST lung-cancer mortality by 14.2\%. The global representation reaches INSPECT Recall@10 of 33.09\% and 32.04\% for text-to-image and image-to-text retrieval, respectively. Across organ-related tasks, anatomically matched representations provide stronger task-relevant signal, while the global representation retains broad utility. OrganLens offers a scalable approach to organ-specific CT representation learning with a shared encoder. More broadly, it provides the medical research community with a reusable framework for studying organ-specific disease across cohorts and clinical endpoints.

  • 5 authors
·
Jul 27

Do 3D Medical Foundation Models See Through MRI Artifacts? A Controlled Study of Representation Robustness

Self-supervised 3D medical foundation models are increasingly used as general-purpose feature extractors, yet their sensitivity to MRI artifacts remains poorly understood. We present a controlled evaluation of representation robustness across five pretrained 3D encoders spanning different architectures, objectives, pretraining domains, and dataset scales. Using BraTS-Africa cases with four MRI sequences, we generate seven frequency- and image-domain artifacts at five predefined corruption settings. Robustness is assessed using linear centered kernel alignment (CKA), RankMe, and UMAP, complemented by an independent segmentation-consistency analysis. We find that robustness is strongly model- and artifact-dependent. 3DINO exhibits the most consistently stable representations, while BrainIAC is highly sensitive to several corruptions; NeuroVFM, BrainFM, and Neuro-SimCLR show intermediate but distinct artifact-specific profiles. Across many conditions, CKA decreases substantially while RankMe remains comparatively stable, indicating that artifacts often distort representation geometry without causing dimensional collapse. Segmentation consistency also degrades under corruption, particularly for ghosting and Rician noise, but aligns only partially with representation-level robustness. These findings show that larger-scale or domain-specific pretraining alone does not guarantee artifact invariance and motivate explicit robustness evaluation before deploying 3D foundation models in heterogeneous MRI settings.

  • 3 authors
·
Aug 5

When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation

Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningful alternative: parameter-frozen inference enhancement(PIE). We use a source-trained segmenter that learns about anatomy-preserving scale and flip views, maps their predictions back to the native location, and averages the probabilities. We do not modify the weights of the model or the normalization statistics. On a cardiac MRI stream from M\&Ms, which is trained on vendor A and evaluated sequentially on vendors B, C, and D, PIE has 0.7786 mean Dice, compared to 0.7680 for source-only inference and 0.7388--0.7416 for five other online-adaptation baselines. The controlled ablations show that performance saturates at 28 views, and confidence weighting, class-prior correction, connected-component filtering, morphological refinement, and inter-slice smoothing have no effect or cause negative transfer. Qualitative results on cardiac MRI and fundus images are also consistent with the frozen ensemble keeping thinner and nested anatomical structures. These results provide a strong, stable baseline for medical CTTA and expose an important failure mode: adaptation and handcrafted refinement can be less reliable than carefully designed inference.

  • 1 authors
·
Sep 17

A Vision-language Framework for Comparative Reasoning in Radiology

Medical imaging artificial intelligence has achieved strong performance in isolated image interpretation, but remains poorly aligned with radiological practice, where diagnosis and follow-up rely on comparison across prior studies and analogous reference cases. Here we formulate radiological comparison as an entity-aware cross-image reasoning problem and introduce a framework that supports both reference-case retrieval and temporal comparative interpretation. We construct MedReCo-DB, a large-scale comparative imaging resource derived from routine image-report pairs, comprising more than 690,000 images from over 160,000 patients across eight institutions, four countries and seven imaging modalities. Reports are decomposed into anatomical structures, abnormal findings and pathological conditions to provide supervision for entity-conditioned retrieval and comparative visual question answering. Using this resource, we develop MedReCo, an entity-aware visual encoder for controllable retrieval of clinically analogous cases, and MedReCo-VLM, a vision--language extension for generative interpretation of interval change. Across internal, external and cross-center evaluations, MedReCo achieved the highest Recall@1 in all 12 internal retrieval settings and improved external retrieval by a mean of 6.0 percentage points. In clinically confusable differential groups, it consistently outperformed the strongest baselines. MedReCo-VLM achieved the best performance across all comparative generation evaluations and improved longitudinal follow-up accuracy by 14.5-46.5 percentage points on chest radiographs and 13.0-27.9 percentage points on CT. These findings suggest that entity-aware comparative reasoning can be learned from routine clinical data at scale and may provide a more clinically aligned foundation for medical imaging AI.

  • 8 authors
·
Jun 7